3-12
220 Dauntless
Section 3 • Systems & Components Overview & Operation
R
Fresh Water Shower
The freshwater shower is located on the starboard
side of the aft cockpit and has an enclosure that the
shower head and hose fit into. The shower hose
extends about 6 ft. (1.82m). Once the system has been
pressurized there is a button on the back of the shower
head which, when pressed, will activate the shower.
Maintenance
Very little maintenance is required for the freshwater
system, other than annual disinfecting and
winterizing. Periodically check the entire system to
assure that the hose connections, tube fittings,
electrical connections and mounting bolts are
properly secured, and free of chafing
Fresh Water System
Fig. 3.12.1
Fresh Water Pump
The freshwater pump will need to be activated to
provide pressure to the system. The freshwater pump
is operated by pressing the switch marked “FRESH
WATER” on the instrument panel. This draws water
from the holding tank and provides pressure to the
shower located in the aft starboard cockpit. You can
reach the freshwater pump through an access hatch
located on the aft wall of the control console interior.
Before you fill the freshwater system it is vital that it
be properly disinfected. Ask your dealer if this has
been done.
The following procedure is recommended to disinfect
the freshwater system:
Fresh Water Fill
There is a freshwater fill located on the port side of
the console. The freshwater tank has a capacity of
12 Gal. (45.4L). Fill the tank only from a source
known to provide safe, pure drinking water. Use only
a plastic hose to fill the water tank. Using a rubber
hose can give the water a disagreeable taste.
1. Flush the entire system thoroughly by
allowing potable water to flow through it.
2. Drain the system completely.
3. Fill the entire system with an approved
disinfecting solution (check with your
dealer for recommendations) and follow the
method prescribed by the manufacturer.
4. After disinfecting, drain the entire system.
5. Flush the entire system thoroughly several
more times with potable water.
6. Now the system is ready for use, fill with
potable water.
This should be done annually or before using the
system if it has been laid up for an extended amount
of time.
1
2
12 GAL (45.4 L) FRESH WATER TANK
FRESH WATER FILL
CONTROL CONSOLE
FRESH WATER PUMP
FRESH WATER SHOWER
3
4
1
2
3
FWD
5
5
4