background image

3

3. TO THE USER

4. TO THE FITTER

5. PRINCIPLES OF OPERATION

6. APPLICATION

7. WARNINGS

List of diagrams

Fig 1 Straight Housing - Complete product  Fig 10 Angled Housing - Tighten screws

Fig 2 Straight Housing - Width and height 

Fig 11 Angled Housing - Screw covers

Fig 3 Straight Housing - Drill hole   

Fig 12 Angled Housing - Insert hose

Fig 4a Straight Housing - Insert housing 

Fig 13a Plumbing - Mixer models

Fig 4b Straight Housing - Secure locking nut  Fig 13b Fitting plumbing – Mixer models

Fig 5 Straight Housing - Insert hose 

Fig 14 Plumbing and hose installed

Fig 6 Angled Housing - Complete product 

Fig 15 Plumbing connection - Cold models

Fig 7 Angled Housing - Width and height 

Fig 16 Maintenance - mixer models

Fig 8 Angled Housing - Drill hole 

 

Fig 17 Operation - Removing handset

Fig 9 Angled Housing - Insert housing 

Fig 18 Operation - Twist handset

Read the following carefully before installation

WARNING:

 Please note that incorrect installation may invalidate the warranty.

Check that the product is suitable for the intended application, follow installation 

instructions and ensure all relevant personnel read the points listed below. Also ensure 

that these installation instructions are passed on to the end user.

The Whale Twist® Deck Shower has a unique innovative handset with temperature 

�������������������������������������������

lines of the boat deck. All Whale Twist® models require only a single circular hole to be 

cut and simple plumbing to install.

The Whale T�������������������������������������

surfaces on the deck or transom of recreational marine vessels or vehicles. If it 

is intended for use for any other purpose or with any other liquid, it is the user’s 

responsibility to ensure that the shower is suitable for the intended use and, in 

particular, that the materials are fully compatible with the liquids to be used.

Temperature Settings – To prevent scalding (regardless of the water 

heating method or the control devices used), the temperature for the hot 

water supplied to the faucets and showers should be controlled in the 

range of 43 ºC to 60 ºC (110 º F to 140 º F) with a fail safe set at 82 ºC 

(180 ºF).

Summary of Contents for Twist DS0003B

Page 1: ......

Page 2: ...and white Straight chrome and Angled white 2 1m 6 9ft DS0006 Mixer 2 5m 8 2ft DS0013B Straight chrome DS0014B Angled white DS0211B Cold Only Straight chrome 2 1m 6 9ft DS0212B Angled white DS0213B Bla...

Page 3: ...rect installation may invalidate the warranty Check that the product is suitable for the intended application follow installation instructions and ensure all relevant personnel read the points listed...

Page 4: ...incl 1 Straight housing 1 Locking nut 1 WX1532B adaptor 1 2 BSP female STEP 1 Choose a suitable location for the shower to be installed The unique horizontal or angled plane Ensure for the handset an...

Page 5: ...pport rings supplied black red and blue 2 Screw covers 1 Valve housing with temporary shut off valve attached includes 2 retaining screws 2 WX1532B adaptor 1 2 BSP female supplied with retail models o...

Page 6: ...il almost disengaged from the threaded part STEP 4 Ensure the black coloured support ring is in place behind the housing If the housing is to be placed on a curved surface replace this with the approp...

Page 7: ...lumbing details PLUMBING PREPARATION STEP 1 Turn off electrics open all faucets and showers hot and cold to depressurize the system and remove the existing shower STEP 2 Prepare hot and cold plumbing...

Page 8: ...p clamp to bulkhead ensuring it is located at least 300 mm 12 from the valve housing See Fig 14 Note In order to securely fasten the unit ensure that the p clamp mounting surface is at least 19mm 3 4...

Page 9: ...See Fig 16a 16b and 16c This allows you to use the freshwater system until the new hose is installed STEP 1 Pull handset gently from the housing See Fig 17 STEP 2 Set flow temperature Temperature sett...

Page 10: ...apy water do not use any chemical cleaning agents Pump may not be operating Valve housing is not in On position Check pump is operating Check valve housing is in locked on position See Fig 14 15 TROUB...

Page 11: ...n Patent number 2007231705 European Patent number 07119601 8 USA Patent number 11 814640 Norway Patent number 0621530 5 UK Patent number 0711496 0 New Zealand Patent number 562931 UK Patent number 071...

Reviews: