![Whale GW0500 Manual Download Page 2](http://html1.mh-extra.com/html/whale/gw0500/gw0500_manual_967136002.webp)
Whale
®
Shower Waste System
Thank you for purchasing this Whale® product. For over 70 years Whale® has led the way in the design and
manufacture of freshwater and waste systems including - plumbing, faucets, showers and pumps for low voltage
applications. The company and its products have built a reputation for quality, reliability and innovation backed up by
excellent customer service. For information on our full product range visit: www.whalepumps.com
* Flow rates are stated in accordance with ABYC recommendations at a voltage of 13.6 V d.c.
The Whale® Shower Waste System is designed to collect waste water from shower trays and sinks, then automatically
trigger the electric field sensor to activate the pump.
Read the following instructions carefully before installation and use of equipment.
Check that the product is suitable for the intended application, follow these installation instructions and ensure all
relevant personnel read the points listed below. Also ensure that these operating instructions are passed on to the end
user.
This Whale Shower Sump System is designed for use in marine vessels to pump grey waste water only.
1 x Whale® Shower Sump System including pump, switch and filter
WARNING:
Please note that incorrect installation may invalidate the warranty.
Preparation - Always disconnect power sources before installing.
Location
1.
2.
3.
1. SPECIFICATION
Model Number
GW0500(B)
GW0950(B)
GW0954(B)
Open Flow Rate @ 13.6 V d.c.
500 US GPH (32 ltrs/min)
950 US GPH (57 ltrs/min)
Flow Rate @ 1m Head
315 US GPH (20 ltrs/min)
600 US GPH (38 ltrs/min)
Voltage D.C.
12V d.c.
12 V d.c.
24 V d.c.
Weight
1.25 kg (2.76 lbs)
1.42 kg (3.13 lbs)
Recommended Fuse Size
2 Amps Automotive
5 Amps Automotive
3 Amps Automotive
Current Draw
1.5 Amps
4 Amps
2 Amps
Inlet Ports
¾” (19mm) / 1” (25mm) / 1 ⅛” (28mm) / 1 ½” (38mm)
Outlet Ports
¾” (19mm) / 1” (25mm)
Materials
Sump Box
- ABS, Polycarbonate,
Strainer
- Stainless Steel,
Pump body
: ABS,
Pump Seals:
Nitrile®,
Pump Impeller
- Acetal,
Electric Field Sensor
- ABS
2. PRINCIPLES OF OPERATION
3. TO THE USER
4. TO THE FITTER
5. APPLICATION
6. WARNINGS
7. PARTS LIST
8. INSTALLATION
ENG
2
Sump
must be
lower than shower and all other drains
Mount in a position with the shortest possible pipe run lengths.
To ensure the electric field sensor switch correctly operates, the sump box
must be
mounted on a flat even surface.
1. NOTE
- This pump
must not
be mounted below the water line when connected to an intake or outlet unless the
system has a vented loop.
2
. POLARITY SENSITIVE
- Reversed wiring will cause switch and pump failure.
3.
Do not
cut wires as this will damage the connections and invalidate the warranty.
4.
Do not
drill through hull, ensure that the product is mounted to additional board or bulkhead.
5.
NOT
suitable for pumping flammable liquids, diesel, chemicals etc. For use in a grey waste water system only.
6. The Whale® Shower Sump System is designed for installation in marine vessels only. If it is intended for use for
any other purpose or with any other liquid, it is the user's responsibility to ensure that the unit is suitable for the
intended use and, in particular, that the materials are fully compatible with the liquids to be used. The Whale®
Shower Sump System is
NOT
suitable for domestic applications.
7. With all applications, it is important that a system of safe working practice is applied to installation, use and
maintenance. Ensure the electric supply is turned off before commencing installation.
8. Electrical wiring
must be
carried out by a qualified electrician.
Summary of Contents for GW0500
Page 30: ...NOTES 30...
Page 31: ...NOTES 31...