3.4
Installation
3.4.1
Preparing for the installation
Check that there is sufficient room for the machine at the installation location.
•
Check that correct connections are available for water, electricity, drainage
and possibly steam at the installation location. See TECHNICAL
SPECIFICATIONS.
•
Check that the overheating protection device is reset.
3.4.2
Positioning the machine
Check the following points before the machine is placed in position:
•
Check that the fuse for the machine at the site is off, blocked and that
outgoing electrical circuits from the machine are non-live.
•
Remove the protective plastic on the sides which are to be stood against a
wall.
•
The distance between the wall and machine should be at least 20 mm.
•
If the machine is to be corner-loaded, it must be positioned with the control
panel furthest away from the wall.
Put the machine in position and check that the machine and any accessories are
horizontal using a spirit level. Place the spirit level on the join between the
machine tank and the upper part. Adjust the height with the legs.
Check with a spirit level that the machine is horizontal
Once the machine has been filled with water, do another check to make sure the
machine is horizontal.
Inst_plac