Westweld LTD
Office:
No.51, Xuefu Avenue, Nanan, Chongqing 400074 , China
11
3.2 Operation steps
Figure 1
Figure 2
Step 1
: Turn on the main power switch (Figure 1) Check the emergency stop button on the front
panel (Figure 2) Add water (distilled or pure water) to the chiller (When the temperature is lower
than 4
℃
, special laser antifreeze is required)
Figure 3
Figure 4
Step 2:
Turn on the key switch on the front panel, press the "power on" green button;
Step 3:
Open the switch behind the laser source (Figure 3) and open the water chiller (Figure 4)
Step 4:
After the system is started, set the laser welding parameters through the touch screen (see
Chapter 3.2 for specific settings);
Step 5:
After the laser parameters are set, turn on the laser enable switch on the touch screen;
Step 6:
Wear the laser protection glasses, clip the safety ground clamp while the handheld welding
head on the work piece (ensure conductivity), the welding head contacts the work piece at the part
to be welded, and the finger presses the button on the handle of the handheld head, the head will
start welding work.
Step 7:
After use, release the welding button, release the safety ground clamp, turn off the laser