Pairing

 

Sensors

 

Pairing

 

is

 

the

 

process

 

of

 

linking

 

new

 

sensors

 

to

 

your

 

main

 

Alarm/Siren

 

module.

 

This

 

is

 

a

 

similar

 

process

 

to

 

pairing

 

a

 

Bluetooth

 

headset

 

with

 

a

 

Cell

 

phone.

 

First

 

the

 

main

 

Siren

 

module

 

is

 

put

 

into

 

pair

 

mode

 

so

 

that

 

it

 

searches

 

for

 

available

 

sensors

 

to

 

pair

 

with

 

and

 

then

 

a

 

sensor

 

is

 

put

 

into

 

pair

 

mode

 

to

 

link

 

it

 

to

 

the

 

Siren.

  

This

 

process

 

is

 

described

 

in

 

detail

 

below:

 

Putting

 

Alarm

 

Siren

 

into

 

Pair

 

Mode

 

There

 

are

 

3

 

ways

 

of

 

putting

 

the

 

Alarm

 

Siren

 

into

 

pair

 

mode.

 

The

 

first

 

is

 

at

 

time

 

of

 

initial

 

battery

 

installation

 

and

 

the

 

others

 

are

 

typically

 

used

 

when

 

adding

 

a

 

sensor

 

to

 

an

 

existing

 

system

 

and

 

utilize

 

either

 

the

 

PIN

 

Pad

 

or

 

the

 

Key

 

Fob

 

to

 

place

 

the

 

Alarm

 

Siren

 

into

 

pair

 

mode.

 

Method

 

A

 

 

button

 

inside

 

the

 

Alarm

 

Siren

 

 

 

 
 
 

 

 

Install

 

the

 

three

 

AA

 

batteries

 

into

 

the

 

main

 

Alarm/Siren

 

unit.

  

 

Press

 

and

 

release

 

the

 

black

 

program

 

button

 

located

 

on

 

the

 

circuit

 

board

 

next

 

to

 

the

 

battery

 

compartment.

  

 

The

 

unit

 

will

 

beep

 

twice,

 

green

 

LED

 

flashes

 

slowly

 

searching

 

for

 

a

 

signal

 

for

 

the

 

next

 

60

 

seconds.

   

 

If

 

any

 

of

 

the

 

LED

 

indicator(s)

 

flash

 

Red

 

rapidly,

 

the

 

pairing

 

attempt

 

was

 

unsuccessful

 

and

 

you

 

will

 

need

 

to

 

start

 

the

 

pairing

 

process

 

again.

 

Method

 

B

 

 

using

 

the

 

PIN

 

Pad

 

 
 
 

 

 

 

Using

 

the

 

PIN

 

Pad,

 

hold

 

down

 

the

 

#

 

key

 

for

 

3

 

seconds.

 

 

The

 

red

 

PIN

 

Pad

 

lights

 

will

 

begin

 

to

 

flash.

   

 

Wait

 

until

 

the

 

lights

 

on

 

the

 

PIN

 

Pad

 

stop

 

flashing

 

 

Enter

 

1

6

#

  

 

The

 

Siren

 

will

 

beep

 

twice,

 

its

 

green

 

LED

 

flashes

 

slowly

 

searching

 

for

 

a

 

signal

 

for

 

the

 

next

 

60

 

seconds.

   

 

If

 

any

 

of

 

the

 

LED

 

indicator(s)

 

flash

 

Red

 

rapidly,

 

the

 

pairing

 

attempt

 

was

 

unsuccessful

 

and

 

you

 

will

 

need

 

to

 

invoke

 

the

 

pairing

 

process

 

again.

 

 

Summary of Contents for 9000P

Page 1: ...9000P Wireless Alarm Owner s Manual ...

Page 2: ...Alarm 4 Panic Mode 5 Diagnostics 5 What triggered my Alarm 5 Low Battery Warning 6 Low Battery Detection for a specific sensor 6 Pairing Sensors 8 Putting Alarm Siren into Pair Mode 8 Pairing a new PIN Pad 9 Pairing a new Key Fob 9 Pairing a DoorGuard Sensor 10 Pairing a PIR Motion Sensor 10 Changing your PIN on the PIN Pad 11 Special Functions 12 PIN Pad Functions 12 Key Fob Functions 12 ...

Page 3: ...our valuable contents This manual describes the key features and functions of your system and how to operate these System Functionality Arming your Alarm The 9000P has 2 options for arming as outlined below Actual arming is done via either your PinPad or your Key FOB Arm Home When arming in home mode the PIR motion sensors will become inactive This will give you the ability to move around the room...

Page 4: ...second giving you time to disarm the alarm before the siren sounds This pre trigger warning sounds like 3 rapid chirps a delay 3 rapid chirps a delay and then 3 final rapid chirps During this pre trigger warning the system must be deactivated disarmed by either the Pin Pad or the Remote Key Fob otherwise the siren will sound Once triggered the siren will sound for 30 seconds and will then rearm Fo...

Page 5: ...ive some extra chirps to provide you with additional information about the condition of the Alarm and sensors as well as information about why the Alarm went off These are described below What triggered my Alarm In the event the system was triggered in your absence when disarming the Alarm you will hear a beep followed by a melody You can then go into diagnostic mode to determine which sensor was ...

Page 6: ...stalled for example 2 PIR movement sensors then it may be useful to find out which actual sensor caused a particular trigger Low Battery Warning General When arming or disarming the system if a low battery condition is detected in either the Alarm Siren or any of the wireless sensors the Siren will emit two extra low frequency beeps If the Siren module itself has a low battery there will be a brie...

Page 7: ...ensor 3 Open each door or compartment that contains a movement sensor You will hear a single beep from the Alarm Siren if the batteries are in good condition Once you locate a sensor with a low battery it will send a signal and you will hear a melody playing there is no visual indicator for door sensors Replace batteries in that sensor and continue to the next sensor and so on 4 Once you have test...

Page 8: ...place the Alarm Siren into pair mode Method A button inside the Alarm Siren Install the three AA batteries into the main Alarm Siren unit Press and release the black program button located on the circuit board next to the battery compartment The unit will beep twice green LED flashes slowly searching for a signal for the next 60 seconds If any of the LED indicator s flash Red rapidly the pairing a...

Page 9: ...ing process again Pairing a new PIN Pad First place the Siren into pairing mode using one of the methods A C described above Once the Alarm Siren is in pair mode hold down the button for 3 seconds Wait until the red lights turns on then flashes rapidly and finally until they stop flashing Enter 1 4 The red lights will flash rapidly on the PIN Pad and the green light on the Alarm Siren will flash r...

Page 10: ... mode press the program button on the DoorGuard circuit board using something like a ballpoint pen The green LED on the DoorGuard circuit board will illuminate and flash slowly as it searches and then rapidly when pairing has been accepted and then goes out Repeat this procedure for each additional sensor s added to the system Note The Red LED on sensor circuit board will flash rapidly upon failur...

Page 11: ...PIN Pad press the button and hold for 3 seconds First a single red light will turn on and then two red lights begin to flash rapidly Wait until the lights stop flashing Enter the change PIN sequence 1 2 3 Three red lights will flash and the PIN Pad will beep Within three seconds enter the old PIN then Lights will flash and the PIN Pad will beep The red light between numbers 1 4 will stay on Now en...

Page 12: ... Hold both top and bottom buttons down simultaneously for 3 seconds The red and green lights will flash on the top button Wait until the lights stop flashing Press the top button as many times as the function indicates see chart below Each time you press the top button it will illuminate green Then press the bottom button to send the function The green light flashes rapidly on the Alarm Siren unit...

Page 13: ... to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does ca...

Reviews: