Universal Attachment

To attach, place the universal attachment on the 

modified shaft body and centre press the attachment 

until it snaps into place. Ensure that it is attached firmly 

with the modified shaft body.

To remove the universal attachment, pull the attachment 

up with both hands.

24 Microtube Foam Attachment

First combine the universal attachment with the microtube attachment. Ensure that 

the foam attachment is secure on the universal platform. Then attach the universal 

attachment to the vortex mixer. Insert the filled microtubes to the foam attachment.

+

=

Summary of Contents for 300 - 4200RPM

Page 1: ...1 PRODUCT MANUAL Digital Vortex Mixer 300 4200RPM Code 664 740...

Page 2: ...e Run function allows for the thorough mixing of the solution The digital display toggles between the speed and time values every five seconds 1 2 Intended Use Intended for general laboratory mixing t...

Page 3: ...Setting Variable 300 to 4200 RPM Timer Setting 0 to 999 minutes min sec display Run Time 1 to 999 minutes and infinite mode Speed Accuracy 10 RPM Pulse Mode Yes programmable pulse Load Capacity 500g m...

Page 4: ...at are not supplied with the unit Is operated with accessories that are not supplied or recommended by the manufacturer Is operated improperly or contrary to the manufacturer s specifications 4 Mainte...

Page 5: ...t away from heat water and direct sunlight to avoid sample temperature issues Do not place the vortex mixer in an area that makes it difficult to operate the unit Instalment and removal of the attachm...

Page 6: ...ersal attachment on the modified shaft body and centre press the attachment until it snaps into place Ensure that it is attached firmly with the modified shaft body To remove the universal attachment...

Page 7: ...1455 sales ca westlab com www westlab com Australia New Zealand United States Canada Microplate Foam Attachment First combine the universal attachment with the microplate attachment Ensure that the f...

Page 8: ...e flexible rubber flask attachment to the universal attachment Ensure that the flask attachment is secure on the universal platform Then attach the universal attachment to the vortex mixer Recommended...

Page 9: ...5391 sales us westlab com www westlab com 1 877 822 1455 sales ca westlab com www westlab com Australia New Zealand United States Canada For the desktop adaptor ensure that the power adaptor and the...

Page 10: ...nclude OFF Stand By Continuous or Touch operation 6 Display The digital display shows the speed value time value and pulse parameters 7 Pulse The pulse button is activated only on continuous mode In p...

Page 11: ...ed with the standard attachment In this mode the vortex action will begin only when the cup attachment is pressed Continuous In Continuous mode the vortex action will start automatically at the set sp...

Page 12: ...pulse mode the ON and OFF times are pre set for five seconds each Meanwhile in the programmable pulse mode the user can set the ON time and OFF time as per their requirements Default pulse ON OFF tim...

Page 13: ...ve For the OFF time set it as infinite For example 10 similar samples require vortex action at x speed for 8 seconds In this scenario set the ON time value as 8 seconds and the OFF time as infinite in...

Page 14: ...Westlab in every discovery...

Reviews: