1.  Attach the universal attachment.
2.  Place the flask on the universal attachment.
3.  Tighten the flask with the flexible rubber attachment. 
4.  Lock the flask to the universal attachment by stretching the rubber attachment to suit.
First place the flask on the universal attachment. Then tighten and lock the flexible rubber 

flask attachment to the universal attachment. Ensure that the flask attachment is secure 

on the universal platform. Then attach the universal attachment to the vortex mixer.

Recommended speed values

Attachments

Image

Maximum Fill

Maximum 

Recommended Speed

24 Microtube 

Foam Attachment

75%

700 RPM

Microplate Foam 

Attachment

75%

700 RPM

Flask Rubber 

Attachment

250ml

400RPM

Connecting the power adaptor

Before connecting the ends, ensure that the vortex mixer is in Stand-By mode and that 

the cup attachment is secure in the modified shaft body.

Connect one side of the power adaptor pin to the rear side of the unit and the other end 

to the main supply as pictured. Ensure that the main switch is not switched ON until 

the adaptor is connected at both ends.

Summary of Contents for 300 - 4200RPM

Page 1: ...1 PRODUCT MANUAL Digital Vortex Mixer 300 4200RPM Code 664 740...

Page 2: ...e Run function allows for the thorough mixing of the solution The digital display toggles between the speed and time values every five seconds 1 2 Intended Use Intended for general laboratory mixing t...

Page 3: ...Setting Variable 300 to 4200 RPM Timer Setting 0 to 999 minutes min sec display Run Time 1 to 999 minutes and infinite mode Speed Accuracy 10 RPM Pulse Mode Yes programmable pulse Load Capacity 500g m...

Page 4: ...at are not supplied with the unit Is operated with accessories that are not supplied or recommended by the manufacturer Is operated improperly or contrary to the manufacturer s specifications 4 Mainte...

Page 5: ...t away from heat water and direct sunlight to avoid sample temperature issues Do not place the vortex mixer in an area that makes it difficult to operate the unit Instalment and removal of the attachm...

Page 6: ...ersal attachment on the modified shaft body and centre press the attachment until it snaps into place Ensure that it is attached firmly with the modified shaft body To remove the universal attachment...

Page 7: ...1455 sales ca westlab com www westlab com Australia New Zealand United States Canada Microplate Foam Attachment First combine the universal attachment with the microplate attachment Ensure that the f...

Page 8: ...e flexible rubber flask attachment to the universal attachment Ensure that the flask attachment is secure on the universal platform Then attach the universal attachment to the vortex mixer Recommended...

Page 9: ...5391 sales us westlab com www westlab com 1 877 822 1455 sales ca westlab com www westlab com Australia New Zealand United States Canada For the desktop adaptor ensure that the power adaptor and the...

Page 10: ...nclude OFF Stand By Continuous or Touch operation 6 Display The digital display shows the speed value time value and pulse parameters 7 Pulse The pulse button is activated only on continuous mode In p...

Page 11: ...ed with the standard attachment In this mode the vortex action will begin only when the cup attachment is pressed Continuous In Continuous mode the vortex action will start automatically at the set sp...

Page 12: ...pulse mode the ON and OFF times are pre set for five seconds each Meanwhile in the programmable pulse mode the user can set the ON time and OFF time as per their requirements Default pulse ON OFF tim...

Page 13: ...ve For the OFF time set it as infinite For example 10 similar samples require vortex action at x speed for 8 seconds In this scenario set the ON time value as 8 seconds and the OFF time as infinite in...

Page 14: ...Westlab in every discovery...

Reviews: