Notes
1)
Don’t put a compressor on its side or turn over.
2)
Please assemble the compressor in your air conditioner rapidly after removing the plugs.
Don’t place the comp. in air for a long time.
Avoid compressor running in reverse caused by connecting electrical wire incorrectly.
4)
In case AC voltage is impressed to compressor the compressor performance will
decrease because of its rotor magnetic force decreasing.
4. Inductance
Familiar error:
1)Sound abnormality
2)Insulation resistance disqualification
5. Step motor
5
3
4
2
1
Test in resistance.
TOOL: Multimeter.
Test the resistance of winding. The stepper motor fails if the resistance of winding is 0
(short circuit) or
∞
(
open circuit
)
.
6. Fuse
Check for continuity of fuse on PCB ASS’Y.
Remove the PCB ASS’Y from the electrical component box. Then pull out the fuse from the
PCB ASS’Y.Check for continuity by a multimeter as shown below.
Fuse
Fuse
6
Summary of Contents for WHU09DHA21S
Page 57: ...2 3 4 5 6 7 8 9 10 11 1 Indoor unit WHU09DHA21S 56 Parts list ...
Page 58: ...12 13 14 15 16 17 18 19 14 15 57 Fan ...
Page 59: ...20 21 22 58 Electrical parts ...
Page 61: ...2 3 4 5 6 7 8 9 10 11 1 60 Indoor unit WHU12DHA21S ...
Page 62: ...12 13 15 16 17 18 19 14 14 15 61 Fan ...
Page 63: ...20 21 22 62 Electrical parts ...
Page 65: ... 64 Indoor unit WHU18DHA21S 2 3 4 5 6 7 8 9 10 11 1 ...
Page 66: ... 65 Fan 12 13 16 17 18 19 20 21 22 14 14 14 15 15 15 ...
Page 67: ... 66 Electrical parts 23 24 25 ...
Page 69: ...Indoor unit WHU24DHA21S 68 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1 ...
Page 70: ... 69 Fan 16 17 18 19 20 21 22 23 18 23 ...
Page 71: ... 70 Electrical parts 24 25 26 27 25 ...
Page 73: ...Indoor unit WHU36DHA21S 72 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 1 ...
Page 74: ... 73 Fan 20 21 22 23 24 25 26 27 22 24 25 27 ...
Page 75: ... 74 Electrical parts 28 29 30 29 31 ...
Page 77: ...Outdoor unit WHU09SZA21S 76 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1 ...
Page 78: ... Refrigerant cycle 77 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 ...
Page 79: ... Electrical parts 78 32 33 34 35 36 37 38 39 40 31 41 ...
Page 81: ...Outdoor unit WHU12SZA21S 80 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1 ...
Page 82: ... Refrigerant cycle 81 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 ...
Page 83: ... Electrical parts 82 32 33 34 35 36 37 38 39 40 31 41 ...
Page 85: ...Outdoor unit WHU18SZA21S 84 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 ...
Page 86: ... Refrigerant cycle 85 17 18 19 20 21 22 23 24 25 26 27 28 29 30 35 31 34 48 32 33 ...
Page 87: ... Electrical parts 86 36 37 38 39 40 41 42 43 45 46 47 44 ...
Page 89: ...Outdoor unit WHU24SZA21S 88 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 1 ...
Page 90: ... Refrigerant cycle 22 23 24 25 26 27 28 29 30 32 33 34 35 36 31 89 37 ...
Page 91: ... Electrical parts 90 38 39 40 42 43 44 45 46 47 48 49 41 ...
Page 93: ...Outdoor unit WHU36SZA21S 92 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 ...
Page 94: ... Refrigerant cycle 93 17 18 19 20 21 22 23 24 25 26 27 28 29 30 32 33 31 ...
Page 95: ... Electrical parts 94 34 35 36 37 38 39 40 42 43 44 45 46 47 48 49 41 ...