Test system flow
Cooling mode
Test system pressure.
Is
the low pressure
normal at service
part ?
The pressure on the
high side.
The pressure on the
low side.
Recharge refrigerant
after air purging with
the vacuum
pump.
Is
the low
pressure no
r
mal
over again?
Air remain
s
at the
refrigerant system.
yes
The system
needs
refrigerant.The
service people must
add
refrigeran
t
.
Doe
s
the low pressure
rise ?
NO
Recharge
refrigerant .
yes
The refrigerant system
is
blocked.
Please check
the Capillary Tube
(
or
electronic
expansion valve)
Is
it blocked?
Unsolder the capillary tube
ASS'Y(or electronic expansion
valve).The capillary tube1 is blown
by N
2
.
Check check valve and 4-
way valve.
If the pressure is
close to static
pressure?
NO
NO
4-way valve collude or
compressor exhaust very
ebb.
yes
NO
yes
Heating mode
Test system
pressure.
Is
the high
pressure normal at
service part ?
The pressure on the
high side.
The pressure on the
low side.
Recharge refrigerant
after air purging with
the vacuum
pump.
Is
the high
pressure normal over
again?
Air remain
s
at the
refrigerant system.
yes
The system
need
s
refrigerant.
The service
people must
add
refrigerant
.
Doe
s the
high pressure rise in
heating mode?
NO
Recharge refrigerant
yes
If the pressure is close
to static pressure?
4-way valve collude or
compressor exhaust every
ebb.
yes
Check heat exchanger and
4-way valve.
NO
The capillary tube
is
blocked.Unsolder the
capillary tube ASS'Y.
The
capillary tube1 and capillary
tube2 is blown by N
2
.
NO
Remove the back
panel.
See
the
capillary tube1 and
capillary tube2.Is it
defrosting?
yes
NO
- 2
3
-
Summary of Contents for WHU09DHA21S
Page 57: ...2 3 4 5 6 7 8 9 10 11 1 Indoor unit WHU09DHA21S 56 Parts list ...
Page 58: ...12 13 14 15 16 17 18 19 14 15 57 Fan ...
Page 59: ...20 21 22 58 Electrical parts ...
Page 61: ...2 3 4 5 6 7 8 9 10 11 1 60 Indoor unit WHU12DHA21S ...
Page 62: ...12 13 15 16 17 18 19 14 14 15 61 Fan ...
Page 63: ...20 21 22 62 Electrical parts ...
Page 65: ... 64 Indoor unit WHU18DHA21S 2 3 4 5 6 7 8 9 10 11 1 ...
Page 66: ... 65 Fan 12 13 16 17 18 19 20 21 22 14 14 14 15 15 15 ...
Page 67: ... 66 Electrical parts 23 24 25 ...
Page 69: ...Indoor unit WHU24DHA21S 68 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1 ...
Page 70: ... 69 Fan 16 17 18 19 20 21 22 23 18 23 ...
Page 71: ... 70 Electrical parts 24 25 26 27 25 ...
Page 73: ...Indoor unit WHU36DHA21S 72 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 1 ...
Page 74: ... 73 Fan 20 21 22 23 24 25 26 27 22 24 25 27 ...
Page 75: ... 74 Electrical parts 28 29 30 29 31 ...
Page 77: ...Outdoor unit WHU09SZA21S 76 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1 ...
Page 78: ... Refrigerant cycle 77 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 ...
Page 79: ... Electrical parts 78 32 33 34 35 36 37 38 39 40 31 41 ...
Page 81: ...Outdoor unit WHU12SZA21S 80 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1 ...
Page 82: ... Refrigerant cycle 81 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 ...
Page 83: ... Electrical parts 82 32 33 34 35 36 37 38 39 40 31 41 ...
Page 85: ...Outdoor unit WHU18SZA21S 84 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 ...
Page 86: ... Refrigerant cycle 85 17 18 19 20 21 22 23 24 25 26 27 28 29 30 35 31 34 48 32 33 ...
Page 87: ... Electrical parts 86 36 37 38 39 40 41 42 43 45 46 47 44 ...
Page 89: ...Outdoor unit WHU24SZA21S 88 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 1 ...
Page 90: ... Refrigerant cycle 22 23 24 25 26 27 28 29 30 32 33 34 35 36 31 89 37 ...
Page 91: ... Electrical parts 90 38 39 40 42 43 44 45 46 47 48 49 41 ...
Page 93: ...Outdoor unit WHU36SZA21S 92 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 ...
Page 94: ... Refrigerant cycle 93 17 18 19 20 21 22 23 24 25 26 27 28 29 30 32 33 31 ...
Page 95: ... Electrical parts 94 34 35 36 37 38 39 40 42 43 44 45 46 47 48 49 41 ...