6.
If an adjustment is required, hold the adjusting nut and
loosen the jam nut.
7.
Turn the adjusting nut to obtain the correct valve lash.
When the valve lash is correct, hold the adjusting nut
and tighten the jam nut to 106 in-lb (12 N•m).
8.
Recheck the valve lash after tightening the jam nut.
9.
Perform this procedure for both the intake and
exhaust valves.
10.
Install the rocker arm cover, gasket and spark plug.
TESTING GFCI OUTLETS
1. Start the generator and allow it to warm up.
2.
Press the test button on the GFCI outlet.
Test Button
Reset Button
3. The reset button should pop out and there will be
no power from the outlets. If the reset button does
not pop out, the GFCI outlet is not working correctly
and must be repaired before the generator can be
operated.
4. Press the reset button to restore power to the outlet.
CLEANING THE GENERATOR
It is important to inspect and clean the generator after
every use.
Clean All Engine Air Inlet and Outlet Ports
– Make sure
all engine air inlet and outlet ports are clean of any dirt and
debris to ensure the engine does not run hot.
Clean All Engine Cooling Fins
– Use a damp rag and
a brush to loosen and remove all dirt on or around the
engine’s cooling fins.
Clean All Alternator Cooling Air Inlets and Exhaust
Ports
– Make sure the cooling air inlets and exhaust ports
of the alternator are free of any debris and obstructions.
Use a vacuum cleaner to remove dirt and debris stuck in
the cooling air inlets and exhaust ports.
General Cleaning of the Generator
– Use a damp rag to
clean all remaining surfaces.
CHECKING AND ADJUSTING VALVE LASH
CAUTION
Checking and adjusting valve lash
must be done when the engine is cold.
1.
Remove the rocker arm cover and carefully remove
the gasket. If the gasket is torn or damaged, it must
be replaced.
2.
Remove the spark plug so the engine can be rotated
more easily.
3.
Rotate the engine to top dead center (TDC) of the
compression stroke. Looking through the spark plug
hole, the piston should be at the top.
4.
Both the rocker arms should be loose at TDC on the
compression stroke. If they are not, rotate the engine
360°.
5.
Insert a feeler gauge between the rocker arm and the
push rod and check for clearance (see Figure 24). See
Table 3 for valve lash specifications.
1
2
3
4
5
Figure 24
(1) Push Rod, (2) Feeler Gauge Area
(3) Rocker Arm, (4) Jam Nut, (5) Adjusting Nut
(Table 3) Standard Valve Lash
Intake Valve
Exhaust Valve
Valve Lash
0.0035 ± 0.0043 in
(0.09 ± 0.11 mm)
0.0043 ± 0.0051 in
(0.11 ± 0.13 mm)
Bolt Torque
8-12N.m
8-12N.m
MAINTENANCE
Summary of Contents for WGen5500
Page 1: ...USER MANUAL WGen5500 Portable Generator 5500 Running Watts 6850 Peak Watts...
Page 8: ...8 Westinghouse Portable Power SAFETY SAFETY LABELS AND DECALS 8 9 7 10 8 9 6 6 7 5 10...
Page 32: ...32 Westinghouse Portable Power WGen5500 SCHEMATIC...
Page 34: ...34 Westinghouse Portable Power Version 07 23 18KD...