Westinghouse Outdoor Power Equipment, LLC | 13
USING FUEL STABILIZER
Adding a fuel stabilizer (not included) extends the usable
life of fuel and helps prevent deposits from forming that
can clog the fuel system. Follow the manufacturer’s
instructions for use.
ALWAYS
mix the correct amount of fuel stabilizer to
gasoline in an approved gasoline container before fueling
the generator. Run the generator for five minutes to allow
the stabilizer to treat the entire fuel system.
FILLING THE FUEL TANK
1.
Turn the generator OFF and allow to cool for a minimum
of two minutes before fueling.
2.
Place the generator on level ground in a well-ventilated
area.
3.
Clean area around fuel cap and remove the cap slowly.
NOTICE
Only fill the tank from an approved gasoline container.
Make sure the gasoline container is internally clean and
in good condition to prevent fuel system contamination.
4.
Slowly add the recommended fuel.
DO NOT
overfill. Fill
only to the red maximum fill ring on the fuel screen filter
visible in the filler neck.
5.
Install the fuel cap.
NOTICE
Fuel can damage paint and plastic. Use caution when
filling the fuel tank. Damage caused by spilled fuel is not
covered under warranty.
NOTICE
Clean the fuel screen filter of debris before and after
each fueling. Remove the fuel screen filter by slightly
compressing it while removing it from the fuel tank.
CONNECT THE BATTERY
A quick-connect battery plug is pre-installed on the battery.
Remove the cable tie securing the plugs then push firmly
to connect them.
Quick-Connect Plug
Note:
The generator is equipped with a battery charging
feature. Once the engine is running, a small charge
will slowly recharge the battery.
ASSEMBLY