background image

6 | Westinghouse Portable Power

DANGER

Never use the generator in a location that is wet or damp. Never expose the generator to rain, 

snow, water spray or standing water while in use. Protect the generator from all hazardous weather 

conditions. Moisture or ice can cause a short circuit or other malfunction in the electrical circuit.

Never operate the generator in an enclosed area. Engine exhaust contains carbon monoxide. Only

operate the generator outside and away from windows, doors and vents.

WARNING

Voltage produced by the generator could result in death or serious injury.

•  Never operate the generator in rain or a flood plain unless proper precautions are taken to avoid 

being subject to rain or a flood.

•  Never use worn or damaged extension cords.

•  Always have a licensed electrician connect the generator to the utility circuit.

•  Never touch an operating generator if the generator is wet or if you have wet hands.

•  Never operate the generator in highly conductive areas such as around metal decking or steel 

works.

•  Always use grounded extension cords. Always use three-wire or double-insulated power tools.

•  Never touch live terminals or bare wires while the generator is operating.

•  Be sure the generator is properly grounded before operating.

WARNING

Gasoline, gasoline vapors & liquid petroleum gas (LPG) are extremely flammable and explosive 

under certain conditions.

•  Always refuel the generator outdoors, in a well-ventilated area.

•  Never remove the fuel cap with the engine running.

•  Never refuel the generator while the engine is running. Always turn engine off and allow the 

generator to cool before refueling.

•  Only fill fuel tank with gasoline.

•  Keep sparks, open flames or other form of ignition (such as matches, cigarettes, static electric 

sources) away when refueling.

•  Never overfill the fuel tank. Leave room for fuel to expand. Overfilling the fuel tank can result in a 

sudden overflow of gasoline and result in spilled gasoline coming in contact with HOT surfaces. 

Spilled fuel can ignite. If fuel is spilled on the generator, wipe up any spills immediately. Dispose 

of rag properly. Allow area of spilled fuel to dry before operating the generator.

•  Wear eye protection while refueling.

•  Never use gasoline as a cleaning agent.

•  Store any containers containing gasoline or propane in a well-ventilated area, away from any 

combustibles or source of ignition.

•  Check for fuel leaks after refueling. Never operate the engine if a fuel leak is discovered.

WARNING

Never operate the generator if powered items overheat, 

electrical output drops, there is sparking, flames or smoke 

coming from the generator, or if the receptacles are 

damaged.
Never use the generator to power medical support 

equipment.

Always remove any tools or other service equipment used 

during maintenance from the generator before operating.

NOTICE

Never modify the generator.

Never operate the generator if it 

vibrates at high levels, if engine 

speed changes greatly or if the

engine misfires often.

Always disconnect tools or 

appliances from the

generator before starting.

GENERAL SAFETY RULES

SAFETY

Summary of Contents for WGen3600DF

Page 1: ...USER MANUAL WGen3600DF Dual Fuel Portable Generator GASOLINE 3600 Running Watts 4650 Peak Watts PROPANE 3240 Running Watts 4180 Peak Watts REMOTE START PUSH BUTTON ELECTRIC START...

Page 2: ...California Proposition 65 Warning The engine exhaust from this product contains chemicals known to the state of California to cause cancer birth defects or other reproductive harm California Propositi...

Page 3: ...NAL INFORMATION GENERATOR INFORMATION First Name ________________________________________ Model Number ______________________________________ Last Name ________________________________________ Serial...

Page 4: ...version Kits 16 Power Cord 17 Using Westinghouse Power Cord 17 Engine Fluids and Fuel 18 Programming Remote Start Key Fob 18 Adding Gasoline to the Fuel Tank 19 Connecting the LPG Propane Tank 19 Swit...

Page 5: ...erts symbol DANGER Indicates a hazardous situation which if not avoided will result in death or serious injury WARNING Indicates a hazardous situation which if not avoided could result in death or ser...

Page 6: ...ea Never remove the fuel cap with the engine running Never refuel the generator while the engine is running Always turn engine off and allow the generator to cool before refueling Only fill fuel tank...

Page 7: ...n u columbus Ohio tats Unis MWE Investments LLC Columbus Ohio 43228 Etats Unis Part N0 Num ro de pi c e Designed in Columbus Ohio USA Made in China Fabriqu en Chine CSA Master Contract Number Num ro d...

Page 8: ...8 Westinghouse Portable Power SAFETY SAFETY LABELS AND DECALS 9 10 8 11 9 10 7 7 4 11 8...

Page 9: ...highly explosive and flammable Explosions and fire can cause severe burns or death Gasoline and gasoline vapor Gas Gasoline is highly flammable and explosive Gas expands and contracts with different...

Page 10: ...s to reveal the manual 3 Remove the Wheel Kit Accessories cardboard box 4 Carefully cut two sides of the carton to remove the generator WHAT COMES IN THE BOX Owners Manual Quick Start Guide Maintenanc...

Page 11: ...mbled the wheel kit is not intended for on road use The wheel kit is designed for use on this generator only INSTALLING FEET TO FRAME 1 Place generator on a flat surface 2 Place a piece of cardboard o...

Page 12: ...he positive battery cable red boot first when connecting battery cables ALWAYS disconnect the negative battery cable black boot first when disconnecting battery cables NEVER connect the negative batte...

Page 13: ...ncluded for electric start models Oil Fill Plug Dipstick Must be removed to add and check oil FEATURES Oil Drain Plug Must be removed to drain engine oil Propane Hook Up Hook up your propane tank with...

Page 14: ...ed when servicing the engine or the spark plug CARB Canister Required for models sold into and used in California Muffler and Spark Arrester Avoid contact until engine is cooled down Spark arrestor pr...

Page 15: ...red through the 120 volt duplex outlets to 20amps Ground Terminal The ground terminal is used to ground the generator Fuel Selector Switch Select and turn on gas or propane Push Start Button Push for...

Page 16: ...will be reduced approximately 3 5 for every 1000ft of increased altitude from sea level This is a natural occurrence and cannot be adjusted by engine Increased exhaust emissions can also result due to...

Page 17: ...nce on the top line of the chart Then select the rated amperage of the generator on the left side of the chart Where the two meet is the size of the conductor required for the application The WCG25 po...

Page 18: ...in properly Make sure to vary to load occasionally to allow stator windings to heat and cool Adjusting the load will also help seat piston rings Check oil more often during the first couple times of o...

Page 19: ...e tank valve is in the off position 3 Make sure the fuel selector switch on the generator control panel is pointing downward to Propane 4 Remove the plastic cover on the generator propane inlet valve...

Page 20: ...16 Propane connection is secure with no leaks or damage See Connecting LPG Tank on page 19 DANGER Never use the generator in a location that is wet or damp Never expose the generator to rain snow wat...

Page 21: ...ve on the propane tank 5 Switch the engine switch to RUN see Figure 11 6 Choose starting method a Recoil Start Move the choke to the right then firmly grasp and pull the recoil handle slowly until you...

Page 22: ...Internal pressure can build in the engine crankcase while the engine is running Removing the oil fill plug dipstick while the engine is hot can cause extremely hot oil to spray out of the crankcase a...

Page 23: ...Oil Check Level Change Change Cooling Features Check Clean Air Filter Check Clean Replace Spark Plug Check Clean Replace Spark Arrestor Check Clean Service more frequently if operating in dry and dus...

Page 24: ...stick 5 Remove oil fill plug dipstick see Figure 18 below Figure 18 Oil Fill Plug Dipstick 6 Check oil level When checking the engine oil remove the oil fill plug dipstick and wipe it clean Thread the...

Page 25: ...apply slow but firm squeezing action 6 Rinse in clean water by submerging the air filter elements in fresh water and applying a slow squeezing action CHANGING ENGINE OIL 1 Stop the engine 2 Let engin...

Page 26: ...e the spark plug boot by firmly pulling the plastic spark plug boot handle directly away from the engine see Figure 23 NOTICE Never apply any side load or move the spark plug laterally when removing t...

Page 27: ...the fumes can come in contact with an ignition source such as a 1 pilot light of a stove water heater clothes dryer or any other gas appliance or 2 spark from an electric appliance NOTICE Gasoline st...

Page 28: ...instructions may result in conditions that can lead to voiding of the EPA certification or product warranty serious personal injury property damage or even death TROUBLESHOOTING PROBLEM POTENTIAL CAU...

Page 29: ...or dispersing after operation 3 Normal no remedy is needed Poor performance or engine stalling on propane 1 Propane fuel line kinked or crushed 1 Inspect propane fuel line and remove kinks or other ob...

Page 30: ...30 Westinghouse Portable Power WGen3600DF EXPLODED VIEW...

Page 31: ...110502 Spring Washer 26 110518 Muffler Assy 27 150551 Fuel Tank 27 1 150506 Fuel Strainer 28 120541 M5X25 29 150547 M6 Washer 30 150520 Carbon Canister 31 120528 Ground Strap 32 120533 M6 Washer 33 1...

Page 32: ...0503 M8X30 15 180547 Cylinder Head Gasket 16 180553 Heat Shield 17 120505 M6X12 18 180597 Dust Plate 19 180567 M6X20 20 180598 Flywheel Assy 21 180539 Engine Cooling Fan 22 180538 Starter Cup 23 18053...

Page 33: ...Westinghouse Portable Power 33 WGen3600DF SCHEMATIC W Gen3600DF...

Page 34: ...34 Westinghouse Portable Power MAINTENANCE NOTES...

Page 35: ...Westinghouse Portable Power 35 MAINTENANCE NOTES...

Page 36: ...36 Westinghouse Portable Power Version 9 25 17KD...

Reviews: