20 | Westinghouse Portable Power
SWITCHING FUEL SOURCES
BEFORE ADDING GAS TO THE TANK
PLEASE REVIEW FUEL SAFETY
SECTION ON PAGE 9
The below assumes that the propane fuel line is already
attached to the generator securely and safely.
While the unit is running simply turn the FUEL
SELECTOR knob to the desired fuel source. If you
want to switch from gasoline to propane make sure the
propane tank valve is open before you switch. When
you move from propane to gasoline shut the propane
valve after you have switched to gas.
NOTICE
If you do not plan on operating the unit on propane do not leave
the propane tank valve open.
When starting on propane the engine may run rough for a few
seconds while it purges gasoline in the carburetor.
If the engine fails when switching fuel sources simply restart the
unit on the fuel source that you switched to.
BEFORE STARTING THE GENERATOR
BEFORE STARTING THE GENERATOR,
REVIEW SAFETY SECTION STARTING
ON PAGE 5.
Before attempting to start the generator,
verify the following:
• The engine is filled with engine oil. See Checking
Engine Oil on page 24.
• The generator is situated in a proper location
(Location Selection on page 16).
• The generator is on a dry surface (Weather and Dry
Surface on page 16).
• All loads are disconnected from the generator (No
Connected Loads on page 16).
• The generator is properly grounded the Generator
(page 16).
• Propane connection is secure with no leaks or
damage. See Connecting LPG Tank on page 19.
DANGER
Never use the generator in a location that is wet or
damp. Never expose the generator to rain, snow,
water spray or standing water while in use. Protect
the generator from all hazardous weather conditions.
Moisture or ice can cause a short circuit or other
malfunction in the electrical circuit.
Never operate the generator in an enclosed area.
Engine exhaust contains carbon monoxide. Only
operate the generator outside and away from
windows, doors and vents.
NOTICE
The engine is equipped with a low oil shutdown switch. If the oil
level becomes low, the engine may shut down and not start until
the oil is filled to the proper level. Poor oil quality may interfere with
the operation of the low oil shutdown switch.
The owner of the generator is responsible to ensure the proper oil
level is maintained during the operation of the generator. Failure to
maintain the proper oil level can result in engine damage.
NOTICE
When operating on LPG it is common for frost to form on the tank
and regulators. This is not an indication of a problem. The amount
of frost that forms can be affected by the size of the container,
the amount of fuel being used, the humidity of the air and other
operating conditions. In standard use this frost may reduce flow
of gas and lower performance. If frost becomes an issue try
exchanging fuel tanks to allow the first tank to warm up. You can
also temporarily warm the tank up by pouring warm water over the
top of the propane tank.
OPERATION
Summary of Contents for WGen3600DF
Page 8: ...8 Westinghouse Portable Power SAFETY SAFETY LABELS AND DECALS 9 10 8 11 9 10 7 7 4 11 8...
Page 30: ...30 Westinghouse Portable Power WGen3600DF EXPLODED VIEW...
Page 33: ...Westinghouse Portable Power 33 WGen3600DF SCHEMATIC W Gen3600DF...
Page 34: ...34 Westinghouse Portable Power MAINTENANCE NOTES...
Page 35: ...Westinghouse Portable Power 35 MAINTENANCE NOTES...
Page 36: ...36 Westinghouse Portable Power Version 9 25 17KD...