22
INSTALLATION OF THE APPLIANCE
Gas model clearance requirement
•
Ensure the appliance is installed in accordance with
clauses 6.2.5 and 6.10.1.1 of AS/NZS 5601.1 or clauses
6.10.1 and 6.10.5 of AS/NZS 5601.2 with regard to
clearances to combustible surfaces and materials,
and clearances to rangehoods and exhaust fans,
to ensure clearances of 200mm from burners to
vertical combustible surfaces observe the minimum
dimension of 100mm from each side of
the cooker to combustible surfaces.
•
Clearances to combustible surfaces may be reduced
if combustible surfaces are protected in accordance
with clause 6.10.1.2 of AS/NZS 5601.1, or clause 6.9.2
of AS/NZS 5601.2.
•
When setting the cooker height, ensure the top of
the cooker is at least 10mm higher than the level
of the benchtop.
installing splashback
Fit splashback to rear of hob with three screws provided.
Cabinet requirements
Model WFE911SB is designed to fit into a 900mm wide
gap between standard kitchen cabinets. The appliance
integrates with the kitchen cabinets by matching
standard height and depth. The cooker may also be
installed at the end of a line of benches or with a free
space either side.
WARNING
WARNING
•
The cooker must be installed and serviced only by
an authorised person.
•
A Certificate of Compliance MUST be supplied to be
kept by the customer.
•
The packing materials must be removed before you
install the cooker.
•
The surrounding kitchen cabinets must be able
to withstand 85°C. Electrolux WILL NOT accept
responsibility for damage caused by installation into
kitchen cabinets which cannot withstand 85°C.
•
The pipes used for installation MUST have sufficient
loops so the cooker can be moved for service
(gas models).
•
The vents, openings and air spaces MUST NOT
be blocked.
•
The appliance is rear vented. This means that moist
air may be expelled from the appliance during use.
Please ensure the surface adjacent to the rear of the
appliance is sufficiently sealed to avoid damage
•
You MUST NOT lift or pull the cooker by the
door handle.
•
The cooker MUST be checked every five years.
•
If the supply cord is damaged,it must be replaced
by the manufacturer,its service agent or similarly
qualified persons in order to avoid a hazard.
• The appliance must not be installed behind a
decorative door in order to avoid overheating.
INSTALLATION