4
CAUTION: For fixtures labeled for outdoor and wet location use, provide a water-tight seal
between the fixture and the mounting surface by using silicone or similar caulking.
NOTE: Underwriters Laboratories (UL) does not require all fixtures to have ground wires. These
fixtures meet all UL specifications.
1. Turn off power at circuit box to avoid possible electric shock.
2. Thread mounting screws (A) into the universal mounting plate or cross bar (B) (see fig. 1).
3. Secure universal mounting plate or cross bar (B) to outlet box (C) with outlet box screws (D)
(not included).
NOTE: Mounting screws (A) must be level for fixture to hang straight.
4. Identify color coding of fixture wires (see fig. 2).
5. To connect wires, take black fixture wire (group A from fig. 2) and place evenly against
black outlet box wire. Do not twist wires.
6. Fit wire connector (H) (see fig. 2) over wires and twist until there is a firm connection. If
wire connector (H) easily comes off, reattach and check again for a firm connection.
7. Repeat steps 7 and 8 with the white (group B from fig. 2) fixture wires and outlet box wires.
8. Partially thread green grounding screw (I) into side hole (J) on universal mounting plate or
cross bar (B) (see fig. 1).
9. Wrap ground wire from fixture around green grounding screw (I) leaving enough excess
wire to then connect ground wire and outlet box wire with wire connector (H), if applicable.
10. Tighten green grounding screw (I). Do not over tighten.
11. Tuck wires inside outlet box (C).
MOUNTING AND WIRING INSTRUCTIONS
FIXTURE ASSEMBLY INSTRUCTIONS
1. Place back plate (K) over mounting screws (A) and mounting nipple (F) (see fig. 1).
2. Secure into place with small cap nuts (L).
3. Open hinged door (N). Install socket cover(s) (O), if applicable.
4. Install lamp(s). Do not exceed recommended wattage.
5. Close hinged door (N).
6. Turn power back on at circuit box.
12 pg_W-125_EFS 12/5/04 7:43 PM Page 4