Fig. 13
elbow
elbow
elbow
aluminum
seal foil
steight flue
glass glue
aluminum
seal foil
aluminum
seal foil
concrete
concrete
sreight flue
sreight flue
a. flue installed through the window
b. flue on the side of the heater
c. flue on the back of the heater
Fig. 12
INSTALLATION
• Use concrete to seal the gap between the flue and the wall. If the flue is installed through the
glass, use the glass glue to seal the gap tightly.
• Cautions for flue installation
• Please use the flue supplied by our company, other flue with different model and specification
is strictly forbidden. Don’t change the speficication of the flue.
• The whole lenght of the flue (A+B+C) should be less than 2m, and the number of the elbow
should not be more than 3, otherwise it will cause results like explosive combustion, flame out
etc... (Fig. 13)
• The installation of the flue must be correct, otherwise the waste gases will flow back and
cause danger. (Fig. 14)