DANGER

Never use the inverter in a location that is wet or damp. Never expose the inverter to rain, snow, 

water spray or standing water while in use. Protect the inverter from all hazardous weather conditions. 

Moisture or ice can cause a short circuit or other malfunction in the electrical circuit.

Never operate the inverter in an enclosed area. Engine exhaust contains carbon monoxide. Only

operate the inverter outside and away from windows, doors and vents.

WARNING

Voltage produced by the inverter could result in death or serious injury.

•  Never operate the inverter in rain or a flood plain unless proper precautions are taken to avoid being 

subject to rain or a flood.

•  Never use worn or damaged extension cords.

•  Always have a licensed electrician connect the inverter to the utility circuit.

•  Never touch an operating inverter if the inverter is wet or if you have wet hands.

•  Never operate the inverter in highly conductive areas such as around metal decking or steel works.

•  Always use grounded extension cords. Always use three-wire or double-insulated power tools.

•  Never touch live terminals or bare wires while the inverter is operating.

•  Be sure the inverter is properly grounded before operating.

WARNING

Gasoline and gasoline vapors are extremely flammable and explosive under certain conditions.

•  Always refuel the generator outdoors, in a well-ventilated area.

•  Never remove the fuel cap with the engine running.

•  Never refuel the inverter while the engine is running. Always turn engine off and allow the generator 

to cool before refueling.

•  Only fill fuel tank with gasoline.

•  Keep sparks, open flames or other form of ignition (such as match, cigarette, static electric source) 

away when refueling.

•  Never overfill the fuel tank. Leave room for fuel to expand. Overfilling the fuel tank can result in a 

sudden overflow of gasoline and result in spilled gasoline coming in contact with HOT surfaces. 

Spilled fuel can ignite. If fuel is spilled on the inverter, wipe up any spills immediately. Dispose of rag 

properly. Allow area of spilled fuel to dry before operating the inverter.

•  Wear eye protection while refueling.

•  Never use gasoline as a cleaning agent.

•  Store any containers containing gasoline in a well-ventilated area, away from any combustibles or 

source of ignition.

•  Check for fuel leaks after refueling. Never operate the engine if a fuel leak is discovered.

WARNING

Never operate the inverter if powered items overheat, 

electrical output drops, there is sparking, flames or smoke 

coming from the inverter, or if the receptacles are damaged.

Never use the inverter to power medical support equipment.

Always remove any tools or other service equipment used 

during maintenance from the inverter before operating.

NOTICE

Never modify the inverter.

Never operate the inverter if it 

vibrates at high levels, if engine 

speed changes greatly or if the

engine misfires often. Always 

disconnect tools or appliances 

from the inverter before starting.

GENERAL SAFETY RULES

SAFETY

Summary of Contents for iGen1200

Page 1: ...USER MANUAL iGen1200 Digital Inverter Generator 1000 Running Watts 1200 Peak Watts FOR MODELS...

Page 2: ...tructions and precautions can cause you and others to be seriously hurt or killed Model Number Running Watts Peak Watts Fuel Tank Size L G Rated Speed RPM Ignition Type Spark plug Engine Disp cc Strok...

Page 3: ...TINGHOUSE PRODUCT REGISTRATION FORM PERSONAL INFORMATION INVERTER INFORMATION First Name ________________________________________ Model Number ______________________________________ Last Name ________...

Page 4: ...11 Power Output and Demand 12 Initial Oil Fill 13 Adding Checking Engine Fluids and Fuel 14 Checking and or Adding Engine Oil 14 Adding Gasoline to the Fuel Tank 14 Starting iGen1200 15 Stopping the I...

Page 5: ...ot avoided could result in death or serious injury CAUTION Indicates a hazardous situation which if not avoided could result in minor or moderate injury NOTICE Indicates a situation which can cause da...

Page 6: ...ever remove the fuel cap with the engine running Never refuel the inverter while the engine is running Always turn engine off and allow the generator to cool before refueling Only fill fuel tank with...

Page 7: ...sonal injury UNPACKING Tools required box cutter or similar device 1 Carefully cut the packing tape on top of the carton 2 Remove socket wrench oil and funnel and save for later 3 Carefully cut two si...

Page 8: ...il Handle Pull to start the engine Engine Control Switch Turns the fuel on and off 1 5 6 7 8 9 2 3 4 2 1 3 4 5 6 7 8 9 Engine Service Panel Remove the panel to access the engine and oil for maintenanc...

Page 9: ...uce the load Push in the reset breaker to reset it Efficiency Mode Switch When turned to the ON position the engine will sense the load needed and run at a slower RPM to save fuel 1 2 3 4 5 6 7 8 9 Gr...

Page 10: ...more often during the first couple times of operating the generator NOTICE Weather will affect engine oil performance Change the type of engine oil used based on weather conditions to suit the engine...

Page 11: ...d on other manufacturers inverters Always ensure that both ends of the paralleling cord are switched off before connecting the inverters INVERTER PARALLELING OPERATION 1 Using only the Westinghouse pa...

Page 12: ...to estimate it A rule of thumb for devices fitted with an electric motor is to apply a starting power multiplier of 1 2 for small hand held or portable devices and a value of 3 5 for larger stationar...

Page 13: ...ING ENGINE OIL REVIEW SAFETY SECTION STARTING ON PAGE 5 NOTICE Engine oil must be added when the inverter is on a flat level surface or an inaccurate reading may result Do not overfill If the engine i...

Page 14: ...engine oil will permanently damage internal engine components The engine is equipped with a low oil shutdown switch If the oil level becomes low the engine may shut down and not start until the oil i...

Page 15: ...l circuit Never operate the inverter in an enclosed area Engine exhaust contains carbon monoxide Only operate the inverter outside and away from windows doors and vents Starting the iGen1200 Be sure t...

Page 16: ...ments Efficiency mode should be used only after the inverter has been warmed up to operating temperature 1 To turn on the efficiency mode press the switch to the ON position 2 If no load is present th...

Page 17: ...the touch prior to performing any maintenance procedure Internal pressure can build in the engine crankcase while the engine is running Removing the oil fill plug dipstick while the engine is hot can...

Page 18: ...e oil as specified in Figure 13 8 Using the supplied oil funnel slowly add engine oil to the engine Stop frequently to check the oil level and avoid overfilling 9 Continue to add oil until the oil is...

Page 19: ...e of used engine oil by dumping the oil into a sewer on the ground or into groundwater or waterways Always be environmentally responsible Follow the guidelines of the EPA or other governmental agencie...

Page 20: ...air filter element by again applying a slow firm squeezing action 9 Return the air filter element to its position in the air cleaner housing 10 Install the air cleaner cover making sure the tabs lock...

Page 21: ...e Figure 21 Figure 21 Remove spark plug with socket wrench MAINTENANCE 7 Place a clean rag over the opening created by the removal of the spark plug to make sure no dirt can get into the combustion ch...

Page 22: ...ain the correct valve lash When the valve lash is correct hold the adjusting nut and tighten the jam nut to 106 in lb 12 N m 8 Recheck the valve lash after tightening the jam nut 9 Perform this proced...

Page 23: ...ylinder wall from corroding during storage 7 Replace the spark plug see Spark Plug Maintenance on page 21 8 Move the inverter to a clean dry place for storage CLEANING THE INVERTER It is important to...

Page 24: ...er see page 14 2 Fuel flow is obstructed 2 Inspect and clean fuel delivery passages 3 Dirty air filter 3 Check and clean the air filter see page 19 4 Low oil level shutdown switch is preventing the un...

Page 25: ...or Main winding R R R W W W Bl Bl Bl R R Y G Bl R Y Bu Bl R Bl W P Bl Bl Bl Bu W Br Gr Br R Generator Engine AC pilot light Overload indicator light Oil warning light Control Panel Reset Bl W Bl W DC...

Page 26: ...26 Westinghouse Portable Power iGen1200 EXPLODED VIEW...

Page 27: ...E 29 FUEL HOSE 30 CLIP FUEL LINE 9 5 31 CLIP FUEL LINE 11X0 8 32 FUEL PUMP 33 SELF TAPPING SCREW M5X16 34 100526 PANEL LEFT NO PART DESCRIPTION 35 150524 OIL DRAIN 36 150523 FUEL TANK CAP SOMP 37 1505...

Page 28: ...28 Westinghouse Portable Power iGen1200 ENGINE VIEW NOTE Parts with no number are not stocked by the manufcturer Please call our service team if you have questions...

Page 29: ...TOR 35 BOLT M5 25 36 STATOR 37 BOLT STUD 38 THE TRIGGER 39 CLIP BOLT 40 100592 CLIP FUEL LINE 41 BOLT STUD 42 SEAT CRANKCASE 43 OIL SEAL NO PART DESCRIPTION 44 TUBE FUEL INLET 45 SWITCH ASSEMBLY OIL L...

Page 30: ...lastic Fuel Tank Capacity Gallons Liters 8 gal 3 L Run Time at 25 Load hrs 9 hrs Run Time at 50 Load hrs 7 hrs Gasoline Fuel Gauge No Choke type Manual Choke Location Side Panel AC Outlets 1 Duplex 12...

Page 31: ...Westinghouse Portable Power 31 Version 6 15 18KD...