TROUBLE SHOOTING

Symptoms

Reasons

Gas valve not open

Gas valve half open

Air in the gas pipe

Remedies

Turn on main valve or

replace the gas

Turn on the main

valve

Several opening the

water inlet gas pressure

ignition

Contact the repairer to

check the gas pressure

valve

Turn on the water

supply main valve

Use after de-frozen

Call repairer to check

water pressure, then

clean the filter

Turn the temperature

and gas rods properly

Open the ventilation

hole to let enough

fresh air in

Replace the batteries

Contact the service

center

Contact the service center

Contact the service

center

Contact the service

center

Re-ignite for use if the

ventilation is good

Continuos 20 minutes

operation

Ignition needle

movement

Water control unit

failure

Heat exchanger clogged

Burner clogged

Power shortage

Insufficient fresh air

Water temperature

control mistake

Inadequate water

supply

Freezing

Cold water valve closed

High

Low

Unsuitable

Pressure

Gas

Indica

tor lights on

(r

ed)

Burning aft

er closing

the w

at

er v

alv
e

High t

emper

atur
e of

w

at

er a

t “high”

Lo

w t
emper

atur
e of

w

at

er a

t “high”

Bump

y noise in

ignition

Abnormal smell

Yello
w flame

Deflagr

at

e in ignition

No ignition aft

er 

opening w

at

er v

alv
e

T

he flame goes out

Summary of Contents for HT351G12

Page 1: ...EATER HT351G12 Note Before operating or installing this gas water heater read this manual and follow all safety rules and operating instructions 12 L 2xAA BATTERIES GAS PRESSURE 2 800 Pa 1 2 1 2 NPT C...

Page 2: ...ter heater Read this Manual before installing and operating and keep for future reference CONTENTS Special Advice 3 Factures Bene ts 3 Parts Name 4 Installation 5 Operation Method 8 Cautions For Safet...

Page 3: ...ccordance to this manual 1 Automatic operation Just turn on the hot water tap or shower hot water will issuc When the tap is turned o the flame will automatically go out Independent control of water o...

Page 4: ...Display Flame regulator Hot water outlet Gas inlet Water flow control Cold water inlet Battery box Fig 1 A B C JSD20 10M 350 636 110 JSD24 12M 350 636 127 Fig 2 Unit mm All pictures are just for refer...

Page 5: ...the wall for venting purpose The ventilation fan shall be installed on top of the water heater and the venting hole shall be at the level lower than the water heater Fig 3 The ame check window of the...

Page 6: ...2 For Town Gas users contact the gas dealer to connect with 15mm pipe 3 After connecting the pipes cheek the connections with soapsuds for gas leak Water Inlet Faucct Remove the drain valve rstly to...

Page 7: ...d there shall be a 10mm hole at the bottom of the vertical part of the duct outside the room for the purpose of draining water drops The outlet of the ue duct shall have a windproof cap which should n...

Page 8: ...tion or a change of gas cylinder air may remain in the gas pipe and it requires several ignition attempts to push the air out of the pipe before the gas can be ignited If a problem comes up after norm...

Page 9: ...ot forget to turn o the gas valve Fig 11 Always check all the gas pipe connectiond with soapsuds to see whether it has gas leakage In case of gas leakage shut o the gas supply and open the windows imm...

Page 10: ...ues gas like carbon monoxide Thus the heater must be xed in a ventilated location Keep exhaust fan running and the ventilation hole opened As this water heater is large volume ue type so ue duct must...

Page 11: ...The Heater Water For Drinking As there is always residuce in the heater the water supplied by the heater is only for general use not for drinking Dealing With The Abnormal Conditions Stop the heater w...

Page 12: ...gularly for any defect Contact service center for any doubt Clean the water lter regularly Check the water leakage regularly When the ame turns from blue to yellow with black smoke contact the service...

Page 13: ...ries Contact the service center Contact the service center Contact the service center Contact the service center Re ignite for use if the ventilation is good Continuos 20 minutes operation Ignition ne...