23
G a s C o n n e c t i o n
Before commencing installation, check to
ensure the type of gas to which the
appliance is intended to be connected
matches the gas type given on the
appliance data plate.
Check the data plate (located behind the
oven door) to determine gas type. A gas
type label is located on the back panel near
the gas inlet.
A 1700mm long flexible hose is supplied in
the pack for installation purposes.
CONNECTING FLEXIBLE HOSE
• Place a spanner on the flats provided on the gas inlet to brace the inlet against the action of
wrenching when connecting the hose to the appliance gas inlet. Failure to do so may damage
the appliance.
• An approved thread sealing tape or compound is required for the connection between the hose
and the appliance gas inlet.
A p p l i a n c e s f o r o p e r a t i o n o n N . G . & S . N . G .
For
N.G.
and
S.N.G
appliances the supplied N.G. regulator must be fitted. For
L.P.G
appliances
(Propane or Universal LP)
the test point fitting supplied must be fitted.
NOTE:
The inlet of the regulator or test point fitting should be fitted to the consumer piping first.
The arrow on the regulator or test point fitting indicates the direction of gas flow. Then connect
the hose to the outlet of the regulator or test point fitting using the swivel connection on the
hose and fibre washer supplied.
Ensure the regulator or test point fitting is in a position that is accessible with the
appliance installed and which will allow the appliance to be withdrawn without
disconnecting the hose.
Check all joints and ensure that connections are sound.
GAS INSTALLATION INFORMATION
Important:
Flat fibre washer
must be installed
(P/No. 115-009-011)
Applian
ce
Gas Flo
w
NG Regulator
(P/No. 294-001-031)
Internal
Flange
Flexible Hose
To
145108 SIMPRD 342-1-541 2/6/08 10:24 AM Page 23
Summary of Contents for GGP475
Page 4: ...4 DESCRIPTION OF YOUR APPLIANCE ...
Page 27: ...27 ...