![Westinghouse 10KPRO Owner'S Manual Download Page 40](http://html1.mh-extra.com/html/westinghouse/10kpro/10kpro_owners-manual_965314040.webp)
40
MAINTENANCE
Cleaning the Air Filter – 8KPRO
The air filter must be cleaned after every 50 hours of
use or 3 months (frequency should be increased if
generator is operated in a dusty environment).
1. Turn off the generator and let it cool for several
minutes if running.
2. Move the generator to a flat, level surface.
3. Unclip the clips on the top and bottom of the air
filter cover
(see Figure 46)
and remove the air filter
cover.
Figure 46 – Removing Air Filter Cover
4. Remove the black coarse outside air filter
(see
Figure 47)
.
Figure 47 – Removing Coarse Outside Air Filter
5. Remove the gray fine inside air filter
(see Figure
48)
.
Figure 48 – Removing Fine Inside Air Filter
Summary of Contents for 10KPRO
Page 1: ......
Page 4: ......
Page 10: ...10 SAFETY SAFETY LABELS AND DECALS 10KPRO 1 3 2 1 6 4 3 5 6 4 2 5 Figure 1 ...
Page 11: ...11 SAFETY 1 3 4 5 2 Class F 2 3 1 4 5 Figure 2 ...
Page 12: ...12 SAFETY SAFETY LABELS AND DECALS 8KPRO 1 3 2 1 5 4 3 5 4 2 Figure 3 ...
Page 13: ...13 SAFETY 2 6 3 1 5 4 1 3 4 5 6 2 Figure 4 ...
Page 52: ......
Page 53: ...MANUAL DEL PROPIETARIO ...
Page 56: ......
Page 62: ...10 SEGURIDAD ETIQUETAS Y CALCOMANÍAS DE SEGURIDAD 10KPRO 1 3 2 1 6 4 3 5 6 4 2 5 Figura 1 ...
Page 63: ...11 SEGURIDAD 1 3 4 5 2 Class F 2 3 1 4 5 Figura 2 ...
Page 64: ...12 SEGURIDAD ETIQUETAS Y CALCOMANÍAS DE SEGURIDAD 8KPRO 1 3 2 1 5 4 3 5 4 2 Figura 3 ...
Page 65: ...13 SEGURIDAD 2 6 3 1 5 4 1 3 4 5 6 2 Figura 4 ...
Page 104: ......
Page 105: ......
Page 106: ......