![Westfalia 83 63 27 Instruction Manual Download Page 17](http://html.mh-extra.com/html/westfalia/83-63-27/83-63-27_instruction-manual_963700017.webp)
Using
13
Bleeder Screw
(6)
Brake
Caliper
(7)
(5)
(9)
Air Pressure
Hose
9. Turn on the air compressor, and set its regulator at 6
– 8 bar (90
to 120 PSI). Never exceed 8 bar (120 PSI). Squeeze the trigger
(9) to create a vacuum in its collecting bottle (5).
10. Use a bleeder screw
wrench
(not
included)
and open the bleeder
screw until the brake fluid
starts flowing into the
collecting bottle.
11. Squeeze the trigger (9)
until the old brake fluid
flows
freely
into
the
collecting bottle (5).
open
close