
52
Operation
Measuring DC Voltage
1. Connect the black measuring cable to the COM jack (9) and
the red measuring cable to the input jack (10).
2. Set the rotary function switch (13) to the V
range position
for measuring voltage. The clamp meter switches into the
AC V range.
3. Press the function switch key SEL (5) to change into DC
voltage measuring mode.
4. Use the range switch key RAN (7) to select auto range mode
or manual range mode.
5. Connect the measuring tips parallel to the voltage source or
load terminals for measurement.
Summary of Contents for 82 04 51
Page 1: ...Westfalia Bedienungsanleitung Nr 109889...
Page 4: ...III bersicht Overview 16...
Page 39: ...34 Notizen...
Page 69: ...64 Notes...