Document: 1846en06.doc
Auth.: TAn
Date: 2011-12-29
Page: 17 av 17
WESTERSTRAND URFABRIK AB
Box 133
Tel. 0506 48 000
Internet::
www.westerstrand.se
545 23 TÖREBODA
Fax. 0506 48 051
E-mail:
Countdown from 1 hour and display format ”Hns”.
Before starting the display shows 1:00:00. After pushing the start button the display shows 00:59:59. The
display do not show hundreds of a second.
After 59 minutes the display will show 00:01:00.
Technical specification
Common
Mains
230 VAC 50Hz ± 10 %
Temperature range
-20˚ C + 40˚ C
Synchronisation
Polarised 24V impulse 1/1, TC, DCF
Accuracy
0.1 sek/24 hour
Running reserve
48 hour
Changing Summer/
Winter
Last Sunday in march, last Sunday in October.
Measure range
temperature sensor
–30 ˚ - +60˚
Accuracy temperature
sensor
1 ˚ C
Temperature measurement
Each minute
Specific for 190131-30
Connection power max.
110W / 0.85A
Size of digits HH:MM:SS
190mm :190mm:140 mm
Dimension (WxHxD)
1070 x 270 x 130
Specific for 190130-30
Connection power max.
55W / 0.43A
Size of digits HH:MM:SS
190mm :190mm:140 mm
Dimension (WxHxD)
1070 x 270 x 90