] and [

] until selected minute is shown. Accept with [YES]. 

 
Display shows "

SS:00

". 

Press [

] and [

] until selected second is shown. Accept with [YES]. 

 
Display shows "

SU :01

". 

Set time for how long the buzzer will sound. (0-9 sec.) 
If 0 sec. is chosen the buzzer is shut off by software. 
Press [

] and [

] until wished buzzer time is shown. Accept with [YES]. 

         
Display shows "

UP

  "  or "

dn

  ". 

Select  "UP" for count up, and  "dn"  for count down. 
Press [NO] until selected text is shown. Press [YES]. 
 
Display shows "

dy

  "  or "S

t

  ". 

Select  "St" for static format display, and  "dy"  for dynamic format display. 
Press [NO] until selected text is shown. Press [YES]. 
 
Display shows '

noAU

' or '

AUto

'. In setting 'AUto' the chronometer starts unconditionally when  

[MODE] is pressed from the clock mode. 
Press [NO] until selected text is shown. Press [YES] 
         
 
Display shows "

HnS

 ", "

Hn

  ", "

nSC

 ", "

nS

  ", "

nnS

 " or "

nnC

 ": 

 
"Hns "  Display shows hours, minutes and seconds. 
"Hn  "   Display shows hours and minutes. 
"nSC "  Display shows minutes, seconds and 1/100s. 
"nS  "   Display shows minutes (0-99) and seconds. 
"nnS "  Display shows minutes (0-9999) and seconds. 
"nnC "  Display shows minutes (0-9999) and 1/100 minutes. 
Press [NO] until selected text is shown. Accept with [YES]. 

 

Dynamic/ Static format 

How time is displayed can be selected by dynamic or static format display. 
If dynamic format is selected the display will show the time according to the example below. 

 
Example dynamic display. 

Countdown from 1 hour and display format  ”Hns”. 
Before starting the display shows 1:00:00.  After pushing the start button the display shows 59:59:99. The 
display now shows hundreds of a second. 
After 59 minutes the display will show 01:00:00. 

 
Example static display. 

Summary of Contents for 190130-30

Page 1: ...An Date 2011 12 29 Page 1 av 17 WESTERSTRAND URFABRIK AB Box 133 Tel 0506 48 000 Internet www westerstrand se 545 23 T REBODA Fax 0506 48 051 E mail info westerstrand se Manual Westerstrand T T displa...

Page 2: ...PPING DCF RADIO 2 WIRE COMPUTER BOARD 6 STRAPPING DCF RADIO 3 WIRE COMPUTER BOARD 7 SYNCHRONISATION 8 CONNECTION TEMPERATURE SENSOR OPTION 9 PROGRAMMING 9 Manual programming time 10 Setting light inte...

Page 3: ...nd temperature in 1 25 seconds intervals This device is for use alternatively as digital clock or as chronometer 7 segments LED digits in dimensions 150 190 250 300 and 450 mm The time and temperature...

Page 4: ...urned off The internal clock continues to keep the correct time for 48 hours After power failure the display is turned on and correct time is shown Installation TC l1 Installation Mount the clock by m...

Page 5: ...terstrand se 545 23 T REBODA Fax 0506 48 051 E mail info westerstrand se Connection Connection synchronisation TC and MIN imp is connected at IMP and IMP V IMP IMP DCF DCF 2 wire is connected V and GN...

Page 6: ...29 Page 6 av 17 WESTERSTRAND URFABRIK AB Box 133 Tel 0506 48 000 Internet www westerstrand se 545 23 T REBODA Fax 0506 48 051 E mail info westerstrand se Strapping TC MIN impulse computer board defaul...

Page 7: ...c Auth TAn Date 2011 12 29 Page 7 av 17 WESTERSTRAND URFABRIK AB Box 133 Tel 0506 48 000 Internet www westerstrand se 545 23 T REBODA Fax 0506 48 051 E mail info westerstrand se Strapping DCF radio 3...

Page 8: ...r next minute impulse It is now synchronised Slave mode Set the T T in slave mode InSL see programming page 10 Set time and wait for next minute impulse It is now working in slave mode TC Set the stra...

Page 9: ...506 48 000 Internet www westerstrand se 545 23 T REBODA Fax 0506 48 051 E mail info westerstrand se Connection temperature sensor option Temperature sensor connection 1 red 2 black 3 Screen 1 2 3 TEMP...

Page 10: ...ction Accept displayed value P Program Enter the displayed function Increase displayed value Manual programming time Push F until display shows Push P display shows year Push P until desired year 00 9...

Page 11: ...y The light intensity for the digits has one minimum and one maximum level The setting levels 1 50 are set in function disp An automatic dimmer function regulates the light intensity between minimum a...

Page 12: ...westerstrand se Setting synchronisation Synchronisation for this model is minute impulse TC DCF or stand alone Push F until display shows Push P for desired synchronisation No synchronisation stand a...

Page 13: ...esired alternating temperature 0 25 Accept with F Display shows Alternating time for display date is 4 seconds Push P for desired alternating time 0 25 Accept with F Push R for entering base mode or p...

Page 14: ...can be set Push F until display shows Push P Display shows 12 hour format or 24 hour format Push P for desired format Push R for entering base mode or push F for next function Function as chronometer...

Page 15: ...is monitored from a remote control unit with seven buttons MODE S S PRESET NO YES och MODE For the change between chronometer and clock S S Start stop PRESET Reset of time Reset can only be done when...

Page 16: ...ows noAU or AUto In setting AUto the chronometer starts unconditionally when MODE is pressed from the clock mode Press NO until selected text is shown Press YES Display shows HnS Hn nSC nS nnS or nnC...

Page 17: ...ow 00 01 00 Technical specification Common Mains 230 VAC 50Hz 10 Temperature range 20 C 40 C Synchronisation Polarised 24V impulse 1 1 TC DCF Accuracy 0 1 sek 24 hour Running reserve 48 hour Changing...

Reviews: