Specifications
WD Scorpio MX375M
8
RELEASED 11/17/10 (WD CONFIDENTIAL)
2679-771293-A01
2.4.2
Input Voltage Requirements
The input voltage requirement for these drives is +5.0V ± 5%.
2.4.3
Ripple
2.5
Environmental Specifications
2.5.1
Shock and Vibration
Table 2-1. Shock and Vibration
Operating Vibration
Drives are tested by applying a random or swept sinusoidal excitation in each linear axis, one axis at a
time. The drive incurs no physical damage and no hard errors while operating and subjected to
continuous vibration not exceeding the level listed in Table 2-1. Operating performance may degrade
during periods of exposure to continuous vibration.
Non-Operating Vibration
Note
: This specification applies to handling and transportation of unmounted drives.
Drives are tested by applying a random or swept sinusoidal excitation in each linear axis, one axis at a
time. The drive incurs no physical damage when subjected to continuous vibration not exceeding the
level listed in Table 2-1.
Drive Generated Vibration
Drives are tested by supporting a single drive horizontally in a free-free state and measuring the side-to-
side vibration. Self vibration may not exceed the level listed in Table 2-1.
Rotational Shock Non-Operating
Drives are tested by applying a rotational force centered around the actuator pivot. The drive incurs no
physical damage when subjected to the rotational force specified in Table 2-1.
+5 VDC
Maximum
Frequency
100 mV (peak-to-peak)
10 KHz - 30 MHz
Shock
Operating (2 ms)
350G
Non-operating (2 ms)
1000G
Note: Half-sine wave, measured without shock isolation and without non-recoverable errors.
Vibration
Operating
0.00459 g2/Hz (10-500 Hz)
Non-operating
0.06984 g2/Hz (10-500 Hz)
Drive Generated Vibration
Operating (average)
0.15 gm-mm
Rotational Shock Non-Operating
Amplitude
50K rad/sec
2
Duration
2 ms