Environmental
phenomena
Basic
standard
Description
Test levels
Temperatures
EN 60068-2-1
EN 60068-2-2
Operating
-40 to +70°C (-40 to +158°F)
ab
Storage and
transport
-55 to +85°C (-67 to +185°F)
Humidity
EN 60068-2-30
Operating
5-95% relative humidity
Storage and
transport
Altitude
Operating
2000 m/70 kPa
Service life
Operating
20 years according to IEC/TR 62380
MTBF
Viper-x12A:
1: 557,000 hours
1: MIL-C217F2, GB, 25°C (+77°F)
2: IEC 62380
Viper-x12A-T3G:
1: 549,000 hours
2: 561,000 hours
Viper-x12A-T5G:
1: 544,000 hours
Vibration
IEC 60068-2-6
(sine)
Operational
2 g rms 5-500 Hz, 5 sweeps
IEC
60068-2-64
(random)
Non-operational
long life
simulation
11.44 m/s² rms 5-150 Hz, 5 hours
2.3 m/s² rms 5-2000 Hz, 5 hours
Shock
IEC
60068-2-27
Operational
10 g, 30 ms, half sine
20 g, 11 ms, saw tooth
100 g, 6 ms, half sine
Enclosure
EN 60950-1
Zinc (front),
Aluminium (rear)
Fire enclosure
Dimension WxHxD
with connectors
See "Dimensions" chapter for details
Weight
1.4 kg
Degree of protection
EN 60529
Enclosure
IP67
c
Cooling
Convection
a
Refer to "Safety and Regulations" chapter regarding touch temperature
b
Operational at +85°C for a limited time
c
Provided all connectors are connected with IP67 cabling or fitted with protective caps (delivered with the unit)
and tightened to the specified torque.
Table 10. Environmental and mechanical conditions