RT-370 User Guide
Page 18 (34)
temperature alarms shall be immediately rectified. See reference document [1] for detailed specification of the
temperature sensors alarms.
•
The internal temperature alarms are adjusted so that the device supports the operating ambient temperatures
for the nominal application scenario, i.e. considering typical power consumption of 7 W
•
In real environment the power consumption will be slightly lower due to the fact that there are not always trains
associated in the AP, typical real installation power consumption is in range 7..9 Watts
4.3.6 Installations at Very High Temperatures
For installations, where the product is operated close to its maximum specified ambient temperature (+55°C
<TAmbient < +70°C), it must be ensured that the natural convection is not blocked by objects nearby.
Figure 8 Installation with blocked airflow shall be
avoided
Figure 9 Installation with free airflow – good
installation