4.2.2 Mechanical Integration, Fixing Points and Connector Positions
The product must be fixed with the four fixing points located at the corners of the product. M6 screws shall be
used for the fixation of the product. The screws shall be tightened with min. 3.0Nm (fixing screw ISO 898/1, quality
class 8.8).
NOTICE
: All four specified fixing points must be used for fixing. The fixing surface should be flat to have all fixing
points connected to the surface.
The product has a membrane vent at the bottom of the product for equalizing pressure changes.
NOTICE
: The vent does not require any maintenance. Any manipulations at the vent are not allowed.
Specification Value
Fixing holes
positions
Fixing holes without threads, for 6 mm screws: four pieces of slot holes, see: Figure 6
0 mm, 92 mm
180 mm, 92 mm
0 mm, 0 mm
180 mm, 0 mm
RT-370 fixing
screws
M6 screws/ 6 mm screw, screw length to be selected by installer based on installation
environment and device weight
Clearance
Slot holes require a clearance of min. 10 mm at the long side of the RT-370 for correct
installation and removal. Clearance for heat transfer is to be considered separately.
Connector
positions
AC POWER
Antenna 1
Antenna 2
Antenna 3
100Base-FX FO
ETH
100Base-TX
ETH
See
Figure 7
Figure 15
See
Figure 7
Figure 13
See
Figure 7
Figure 13
See
Figure 7
Figure 12
See
Figure 7
Figure 14
See
Figure 7
Figure 17
Grounding
See Table 12
Table 11 Fixing points and connector positions
Figure 7 RT-370 connectors