44
6193-5201
Pause Between Requests
Enter the delay between serial request retries in mil-
liseconds
Response Timeout
Enter the serial response timeout in milliseconds – a
serial retry will be sent if a response is not received
within this timeout.
Connection Timeout
Enter the TCP connection timeout in seconds – if no
Modbus/TCP data is received within this timeout then
the TCP connection will be dropped. Set this field to
zero for no timeout.
Maximum Request Retries
Enter the maximum number of request retries per-
formed serially.
Maximum Connections
Enter the maximum number of simultaneous TCP
connections to the server allowed.
3.14 Digital Input/Output
The shared Digital Input/Output pin may be monitored and set via the internal webpage.
As this pin is shared, the Digital Input status will be ON when the Digital Output is set
ON.
The Digital I/O channel can also be configured to provide a status output of the module
communications. If the RM-240 disassociates from another unit (that is, there is no wire-
less link), you can configure the digital output to turn ON (set) or OFF (drop).
3.15 Module Information Configuration
Module Information Webpage Fields
This configuration page is primarily for information purposes. With the exception of the
password, the information entered here is displayed on the root webpage of the RM-240.
Password Configuration
password.
When changing the password on this screen, it will be sent
unencrypted over any wired network. If encryption is ena-
bled on the RM-240, any radio communications are encrypt-
ed, and therefore hidden from radio eavesdroppers. Caution
must only be taken if there are potential eavesdroppers on
the wired network.
Device Name
A text field if you wish to label the particular RM-240.
Owner
A text field for owner name.
Contact
A text field for owner phone number, email address etc.
Description
A text field used for a description of the purpose of the
unit.
Location
A text field used to describe the location of the
RM-240.