46
6193-5201
3.17 Configuration Examples
Setting a RM-240 to Factory Default Settings
Access configuration webpages of RM-240. Refer section
Accessing Configuration inside a
module for the first time, or Modifying an existing configuration.
1. Click on System Tools Menu Item
2. Enter username “user” and password “user”, when prompted for password.
Click on Factory Default Configuration Reset, and wait for unit to reset. When reset, the
LINK LED will flash.
Extending a wired network
Access Point Configuration
Connect straight through
Ethernet cable between PC and
RM-240.
… Ensure configuration PC
and RM-240 are setup to
communicate on the same
network
… Set dipswitch to SETUP
mode.
… Power up unit, and wait for
LINK led to cease flashing.
… Adjust PC network settings
Set Configuration PC network card with network setting of IP address 192.168.0.1,
netmask 255.255.255.0
… Open configuration webpage with Internet Explorer at address http://192.168.0.1XX/
where XX is the last two digits of the serial number
When prompted for password, enter default username “user” and password “user”
Enter “Network”, and select Operating Mode as Access Point.
Select Device Mode as Bridge.
Change the Gateway IP Address to 192.168.0.1
Change the Ethernet and Wireless IP addresses to 192.168.0.200
Change Ethernet and Wireless Subnet masks to 255.255.255.0
Enter a System Address (SSID) string
Select the Radio Encryption required.
Set dipswitch to RUN
Save the changes and unit will restart with new settings.
6XXZhhEd^ci
7g^Y\Z
A6C=J7
&.'#&+-#%#%
'**#'**#'**#%
8a^Zci&
7g^Y\Z
8a^Zci'
7g^Y\Z
:i]ZgcZi9Zk^XZ