background image

4

6641-22310

Note. Fibre Optic Handling

Fibre optic equipment needs special treatment. It is very sensitive to dust and dirt.  
If the fibre will be disconnected from the unit the protective hood on the transmitter/
receiver must be connected. The protective hood must be kept on during transportation. 
The fibre optic cable must also be handle the same way.
If these recommendations are not followed the warranty might be jeopardized.

Cleaning of the optical connectors

In the event of contamination, the optical connectors should only be cleaned by the use 
of recommended cleaning fluids and correct cleaning equipment.
Recommended cleaning fluids:
• Methyl-, ethyl-, isopropyl- or isobutyl-alcohol
• Hexane
• Naphtha

Maintenance

No maintenance is required, as long as the unit is used as intended within the specified 
conditions.

Summary of Contents for RFI-207-F4G-T3G

Page 1: ...Industrial Routing Switch www westermo com Westermo Teleindustri AB User Guide 6641 22310 RedFoxIndustrial S E R I E S WeOS ...

Page 2: ...circumstances shall Westermo be responsible for any loss of data or income or any special incidental and consequential or indirect damages howsoever caused More information about Westermo can be found at the following Internet address http www westermo com License Information This device contains public available software which is under the GPL license For more information see legal pdf included w...

Page 3: ...s designed to meet the Class 1 Laser regulations Care recommendations Follow the care recommendations below to maintain full operation of unit and to fulfil the warranty obligations This unit must not be operating with removed covers or lids Do not attempt to disassemble the unit There are no user serviceable parts inside Do not drop knock or shake the unit rough handling above the specification m...

Page 4: ...re optic cable must also be handle the same way If these recommendations are not followed the warranty might be jeopardized Cleaning of the optical connectors In the event of contamination the optical connectors should only be cleaned by the use of recommended cleaning fluids and correct cleaning equipment Recommended cleaning fluids Methyl ethyl isopropyl or isobutyl alcohol Hexane Naphtha Mainte...

Page 5: ...te measures Agency approvals and standards compliance Art no Denomination Type Approval compliance 3641 4000 3641 4110 3641 4200 3641 4210 3641 4300 3641 4310 3641 4320 RFI 219 T3G RFI 211 T3G RFI 215 F4G T3G RFI 207 F4G T3G RFI 219 F4G T7G RFI 211 F4G T7G RFI 219 F4G T7G F8 EMC EN 50121 4 Railway applications Electromagnetic compatibility Emission and immunity of the signalling and telecommunicat...

Page 6: ... 3 In COM 4 In COM Position Direction description Input output values 1 In Vbus U 5V VDC max I 100 mA max 2 In Out D 3 In Out D 4 Not connected 5 GND Degree of protection IP 40 Ambient temperature 40 C to 70 C Installation spacing Minimum 25 mm above below Minimum 10 mm left right Position Direction description Input output values 1 In out BI_DA Per port U 1 V 4V us I 20 mA Data rate 10 100 1000 M...

Page 7: ...tively isolated to GND PE through a 2kV 1000pF capacitor See user manual for proven transient protection Direction relative this unit 1 10 100 Base TX 5 6 7 8 2 3 4 1000 Base X 1000 Base T 1 5 6 7 8 2 3 4 Position Direction description Input output values 1 In out TD Per port U 1 V 4V us I 20 mA Data rate 10 100 Mbit s 2 In out TD 3 In out RD 4 Not connected 5 Not connected 6 In out RD 7 Not conne...

Page 8: ...te customer specific models References of standards applied for this EC declaration of conformity No Title Issue EN 50121 4 Railway applications Electromagnetic compatibility Emission and immunity of the signalling and telecommunications apparatus 2006 EN 55022 Information technology equipment Radio disturbance characteristics Limits and methods of measurement 2010 EN 55024 Information technology ...

Page 9: ...4 FCC part 15 Enclosure Class B 30 6500 MHz Conducted emission CISPR 16 2 1 DC power ports Telecommunication ports Class B Dielectric strength EN 60950 Signal port to other isolated ports 1 5 kVrms 50 Hz 1 min Power port to other isolated ports 1 5 kVrms 50 Hz 1 min Temperature EN 60068 2 1 EN 60068 2 2 Operating 40 to 70ºC all models Storage Transport 40 to 85ºC all models Maximum surface tempera...

Page 10: ...100 Mbit s Ethernet TX RJ 45 3641 4110 RFI 211 T3G 3 x 10 100 1000 Mbit s Ethernet TX RJ 45 8 x 10 100 Mbit s Ethernet TX RJ 45 3641 4200 RFI 215 F4G T3G 3 x 10 100 1000 Mbit s Ethernet TX RJ 45 8 x 10 100 Mbit s Ethernet TX RJ 45 4 x 100 1000 Mbit s pluggable connections tranceivers supported Ethernet FX or TX SFP 3641 4210 RFI 207 F4G T3G 3 x 10 100 1000 Mbit s Ethernet TX RJ 45 4 x 100 1000 Mbi...

Page 11: ...ach corner The back end also holds the earth connection For detailed ground connection information see section on Earth Connection 2 and 3 slot enclosure The slot on the left will always be occupied by the power and CPU Other slots may vary depending on RedFox model Specification 2 slot enclosure 3 slot enclosure Dimension W x H x D 134 x 105 x 122 mm without connectors 175 x 105 x 122 mm without ...

Page 12: ...s Three RJ 45 connectors with support for Ethernet 1000BaseTX a USB port for easy save load of system configuration and a console port The console connector is a micro USB cable that connects to a FTDI FT232R USB to serial converter internally For drivers please see www ftdichip com and download the appropriate VCP driver For detailed information on LED indicators see section on LED indicators Pow...

Page 13: ...G 0 43 0 60 A 20 VDC 0 19 0 25 A 48 VDC RFI 215 F4G T3G 0 63 0 82 A 20 VDC 0 26 0 33 A 48 VDC RFI 207 F4G T3G 0 55 0 72 A 20 VDC 0 23 0 29 A 48 VDC RFI 219 F4G T7G 0 93 1 12 A 20 VDC 0 38 0 45 A 48 VDC RFI 211 F4G T7G 0 87 1 06 A 20 VDC 0 35 0 43 A 48 VDC RFI 219 F4G T7G F8 1 30 1 47 A 20 VDC 0 52 0 58 A 48 VDC Inrush current 40 mA2s 20 VDC 257 mA2s 60 VDC Startup current 2x Rated current Rated fr...

Page 14: ... a FTDI FT232R USB to serial converter internally For drivers please see www ftdichip com and download the appropriate VCP driver Console Electrical specification USB 2 0 device interface Data rate High speed 480mbit s Circuit type SE LV Maximum supply current 100 mA Isolation to All other except USB Galvanic connection to USB Connection USB Micro B connector in device mode ...

Page 15: ...earthing point within 1 m from this port This earthing point should have a low impedance connection to the conductive enclosure of the apparatus cabinet or similar where the unit is built in This conductive enclosure should be connected to the earthing system of an installation and may be directly connected to the protective earth Refer also to Safety section IO Relay output Connect resistance 30 ...

Page 16: ... BI_DA 3 In Out BI_DB 4 In Out BI_DC 5 In Out BI_DC 6 In Out BI_DB 7 In Out BI_DD 8 In Out BI_DD Shield In Out Connected to PE Position Direction Description 1 Out VBUS 2 In Out D 3 In Out D 4 Out GND Shield In Out Connected to PE Console see more information on page 13 ...

Page 17: ... No 1 Status Output Alarm relay status contact No 2 Status Output Alarm relay status contact No 3 Digital in Input Digital in No 4 Digital in Input Digital in The Status output is a potential free opto isolated normally closed solid state relay This can be configured to monitor various alarm events within the Lynx unit see WeOS Management Guide An external load in series with an external voltage s...

Page 18: ...r GREEN Power OK on DC1 RED DC1 input voltage is below operating voltage limit DC2 OFF Unit has no power GREEN Power OK on DC2 RED DC2 input voltage is below operating voltage limit FRNT OFF FRNT disabled GREEN FRNT OK RED FRNT Error BLINK Unit configured as FRNT Focal Point RSTP OFF RSTP disabled GREEN RSTP enabled BLINK Unit elected as RSTP STP root switch USR1 Configurable see WeOS Management G...

Page 19: ...signalling and telecommunications apparatus and located close to rails Conductive housing Yes Number of ports 8 NOTE Railway installation close to the rails To minimise the risk of interference a shielded cable is recommended when the cable is located inside 3 m boundary to the rails and connected to this port The cable shield should be properly connected 360 to an earthing point within 1 m from t...

Page 20: ...Out TD 2 In Out TD 3 In Out RD 4 Not connected 5 Not connected 6 In Out RD 7 Not connected 8 Not connected Shield In Out Connected to PE Direction relative this unit LED indicators 8 copper ports LED Status Description Copper ports 1 8 OFF No link GREEN Link established GREEN FLASH Data traffic indication YELLOW Port alarm and no link Or if FRNT RSTP or Link Aggregation mode port is blocked ...

Page 21: ...t holding fibre transceiver or copper transceiver Number of ports 4 100 Mbit s or 1000 Mbit s transceiver supported F8 8 SFP slots The F8 interface has eight SFP slots supporting Ethernet 10 100BaseFX Each slot can hold one SFP transceiver for copper or fibre cable For supported transceivers see SFP transceivers user guide art no 6100 0000 available at www westermo com Interface specifications F8 ...

Page 22: ...2 COM COM RSTP FRNT VPN ON DC1 DC2 1 2 1 1 10 100 1000 10 100 Base TX POWER CONSOLE IO 2 3 4 5 6 7 8 2 3 4 LED indicators F4G LED Status Description Fibre ports 1 4 OFF No link GREEN Link established GREEN FLASH Data traffic indication YELLOW Port alarm and no link Or if FRNT RSTP or Link Aggregation mode port is blocked ...

Page 23: ...ansmit port Direction relative this unit 100 1 5 2 6 3 7 4 8 LED indicators F8 LED Status Description Fibre ports 1 8 OFF No link GREEN Link established GREEN FLASH Data traffic indication YELLOW Port alarm and no link Or if FRNT RSTP or Link Aggregation mode port is blocked ...

Page 24: ...pplications assignalling and telecommunications apparatus and located close to rails Conductive housing Yes Number of ports 4 NOTE Railway installation close to the rails To minimise the risk of interference a shielded cable is recommended when the cable is located inside 3 m boundary to the rails and connected to this port The cable shield should be properly connected 360 to an earthing point wit...

Page 25: ... 1000 10 100 1000 10 100 Base TX POWER CONSOLE IO 2 3 4 5 6 7 8 2 3 4 1 5 6 7 8 2 3 4 Position Direction Description Rx In Receive port Tx Out Transmit port LED indicators F4G T4G LED Status Description Copper ports 1 4 Fibre ports 5 8 OFF No link GREEN Link established GREEN FLASH Data traffic indication YELLOW Port alarm and no link Or if FRNT RSTP or Link Aggregation mode port is blocked Direct...

Page 26: ...orts Westermo labelled transceivers only Deviations With copper transceiver 1100 0148 the specified operating temperature on the RFI series is 0 to 50ºC FRNT reconfiguration times can not be guaranteed with copper transceivers ESD Protection www westermo com West ermo Telein dustr i AB User Guide 6100 0000 SFP Transceivers ...

Page 27: ...NSOLE IO 2 3 4 5 6 7 8 2 3 4 1 10 100 Base TX 5 6 7 8 2 3 4 Wall mounting This unit can also be wall mounted see figure Earth connection For correct function the ground connection on the unit needs to be properly connected to a solid ground See figure FRNT DC1 DC2 COM COM RSTP VPN ON DC1 DC2 1 2 1 1 10 100 1000 10 100 Base TX POWER CONSOLE IO 2 3 4 5 6 7 8 2 3 4 FRNT DC1 DC2 COM COM RSTP VPN ON DC...

Page 28: ...apter The Command Line Management Tool in the WeOS management guide Factory default IP address 192 168 2 200 and DHCP client Netmask 255 255 255 0 Gateway Disabled Note If you are not sure about the subnet consult your network administrator Configuration Configure the unit via Webbrowser The unit can easily be configured via a Web browser Open the link http 192 168 2 200 in your web browser and yo...

Page 29: ...it is now ready to be reset to factory default You now have the choice to go ahead with the factory reset or to skip factory reset and boot as normal Go ahead with factory reset Acknowledge that you wish to conduct the factory reset by unplugging the Ethernet cable The ON LED will stop flashing This initiates the factory reset process and the unit will restart with factory default settings When th...

Page 30: ...30 6641 22310 ...

Page 31: ...31 6641 22310 ...

Page 32: ...ce infos westermo fr www westermo fr Germany info westermo de www westermo de North America info westermo com www westermo com Singapore sales westermo com sg www westermo com Sweden info sverige westermo se www westermo se United Kingdom sales westermo co uk www westermo co uk Other Offices Sales Units Westermo Data Communications Westermo SE 640 40 Stora Sundby Sweden Tel 46 16 42 80 00 Fax 46 1...

Reviews: