19
6641-22310
Interface modules
8 copper ports
All ports support category 5e cable or better and can handle cable lengths up to 150 m
(492 ft).
Interface specifications
8 copper ports
Electrical specification
IEEE std 802.3. 2005 Edition
Data rate
10 Mbit/s or 100 Mbit/s, manual or auto
Duplex
Full or half, manual or auto
Circuit type
TNV-1
Transmission range
Up to 150 m with CAT5e cable or better*
Isolation to
All other
Connection
RJ-45 auto MDI/MDI-X
Shielded cable
Not required, except when installed in Railway applications as
signalling and telecommunications apparatus and located close
to rails*
Conductive housing
Yes
Number of ports
8
*
NOTE!
Railway installation close to the rails.
To minimise the risk of interference, a shielded cable is recommended when the cable is located
inside 3 m boundary to the rails and connected to this port.
The cable shield should be properly connected (360°) to an earthing point within 1 m from this
port. This earthing point should have a low impedance connection to the conductive enclosure of
the apparatus cabinet, or similar, where the unit is built-in. This conductive enclosure should be
connected to the earthing system of an installation and may be directly connected to the protective
earth. Refer also to "Safety" section.