background image

4

6641-2223

Safety

Before installation:

Read this manual completely and gather all information on the unit. Make sure that 
you understand it fully. Check that your application does not exceed the safe oper-
ating specifications for this unit. 
This unit should only be installed by qualified personnel. 
This unit should be built-in to an apparatus cabinet, or similar, where access is 
restricted to service personnel only. The power supply wiring must be sufficiently 
fused, recom mended fuse: 4 A slow. It must be possible to manually disconnect 
power.  
Ensure compliance to national installation regulations.  
This unit relies on convection heating. Make sure that it is installed so that the 
ambient temperature is within the specified temperature range, e.g. by avoiding 
obstruction of the airflow around the unit.

Before mounting, using or removing this unit:

Prevent access to hazardous voltage by disconnecting the unit from all power supply. 

WARNING

Do not open connected unit. Hazardous voltage may occur within this unit when 
connected to power supply. 
Before powering-up, a protective earthing conductor must be connected to the
protective earthing terminal and have a cross-sectional area of at least 1.5 mm².
When this unit is operated at an ambient temperature above +55°C (+131°F), 
+55°C (+131°F), the External Surface of Equipment may exceed Touch 
Temperature Limit according to EN/IEC/UL 60950-1. 

To reduce the risk of fire, use only No. 26 AWG or larger telecommunication line 
cord.

Care recommendations

Follow the care recommendations below to maintain full operation of unit and to fulfill 
the warranty obligations. 
This unit must not be operating with removed covers or lids. 
Do not attempt to disassemble the unit. There are not any user serviceable parts inside. 
Do not drop, knock or shake the unit. Rough handling above the specification may cause
damage to internal circuit boards.
Do not use harsh chemicals, cleaning solvents or strong detergents to clean the unit. 
Do not expose the unit to any kind of liquids (rain, beverages, paint etc), unless all  
connectors and the ventilation membrane are sufficiently protected.
Do not use or store the unit in dusty or dirty areas, unless all connectors and the  
ventilation membrane are sufficiently protected. 
Do not cover or bring mechanical force to the ventilation membrane on the back  
of the unit.
If the unit is not working properly, contact the place of purchase, nearest Westermo  
distributor office or Westermo Tech support.

!

!

Summary of Contents for RedFox Rail

Page 1: ...www westermo com RedFox Rail Ethernet switch and router approved for railway usage WeOS...

Page 2: ...2 6641 2223...

Page 3: ...ternet address www westermo com Software tools Related software tools are available in the folder software tools under technical support on the Westermo website License and copyright for included Free...

Page 4: ...ive earthing terminal and have a cross sectional area of at least 1 5 mm When this unit is operated at an ambient temperature above 55 C 131 F 55 C 131 F the External Surface of Equipment may exceed T...

Page 5: ...eated as unsorted municipal waste when disposing of it It needs to be handed over to an applicable collection point for recy cling electrical and electronic equipment By ensuring this product is dispo...

Page 6: ...residential commercial and light industrial environments EN 61000 6 4 Emission industrial environments EN 50155 Railway applications Approval Compliance Safety EN 60950 1 IT equipment Agency approval...

Page 7: ...voltage 60 100 ms 1000 ms 100 ms Radiated emission EN 55011 Limits EN 50121 3 2 Enclosure measurement 40 dB V m QP 30 230 MHz 47 dB V m QP 230 1000 MHz 56 dB V m AVG 1000 3000 MHz 60 dB V m AVG 3000...

Page 8: ...The unique FRNT Fast Recovery of Network Topology technology is the fastest protocol on the market to re configure a network in the event of any failure of a link or hardware RFR 212 FB supports QoS...

Page 9: ...er source capability 600 mA 24 VDC 250 mA 110 VDC Polarity Reverse polarity protected Redundant power input No Isolation to All interfaces and chassis Galvanic connection to None Connection M12 A code...

Page 10: ...V 1 Transmission range 100 m 328 ft Isolation to All interfaces and chassis Galvanic connection to None Connection M12 D coded Shielded cable Yes Conductive housing Yes Miscellaneous FRNT reconfigurat...

Page 11: ...ation to All interfaces but not to chassis Shielded cable NA Miscellaneous USB Configuration Pin number Signal No 1 DN No 2 VBUS No 3 NC No 4 DP No 5 GND The agency approvals and standards compliance...

Page 12: ...12 6641 2223 Location of Interface ports LED s LED indicators LED indicators LED indicators Power USB Configuration Ethernet Earth connect...

Page 13: ...est from Web or CLI FRNT OFF FRNT disabled GREEN FRNT OK RED FRNT Error BLINK Unit configured as FRNT Focal Point RSTP OFF RSTP disabled GREEN RSTP enabled BLINK Unit selected as RSTP root switch USR...

Page 14: ...12 2 X10 2 X12 1 X10 3 X12 4 X10 4 X12 3 Note When by passing a switch approximately 5 m 16 4 ft of the transmission range 100 m 328 ft is consumed As an example if a network is intended to cope with...

Page 15: ...face Connection of cables Recommended tightening torque for the M12 connectors 0 6 Nm Removal Disconnect all cables and unscrew the unit from the wall Time For Replacement 15 minutes Cooling This unit...

Page 16: ...8 55 2 22 4 11 5 0 5 3 0 5 133 0 1 5 144 5 1 5 Material Remark Designation Dimension Description Quantity Pos No 1 1 5 Scale Status Designer Drawing No PaPu Approved 6001 0003 U 01 Sheet 1 1 Denominat...

Page 17: ...he WeOS management guide Factory default IP address 192 168 2 200 Netmask 255 255 255 0 Gateway Disabled Note If you are not sure about the subnet consult your network administrator Configuration Conf...

Page 18: ...fault You now have the choice to go ahead with the factory reset or to skip factory reset and boot as normal Go ahead with factory reset Acknowledge that you wish to conduct the factory reset by unplu...

Page 19: ...19 6641 2223...

Page 20: ...REV D 6641 2223 2019 01 Westermo Network Technologies AB Sweden Westermo SE 640 40 Stora Sundby Sweden Tel 46 16 42 80 00 Fax 46 16 42 80 01 E mail info westermo com www westermo com...

Reviews: