S1 DIP-switch, synchronous mode time frame selection

ON 

 1  2  3 4  5 6  7 8

1.6 ms

ON 

 1  2  3 4  5 6  7 8

26 µs

ON 

 1  2  3 4  5 6  7 8

2.6 µs

ON 

 1  2  3 4  5 6  7 8

416 µs

ON 

 1  2  3 4  5 6  7 8

13 µs

ON 

 1  2  3 4  5 6  7 8

2.1 µs

ON 

 1  2  3 4  5 6  7 8

208 µs

ON 

 1  2  3 4  5 6  7 8

8.6 µs

ON 

 1  2  3 4  5 6  7 8

2 µs

ON 

 1  2  3 4  5 6  7 8

104 µs

ON 

 1  2  3 4  5 6  7 8

4.3 µs

ON 

 1  2  3 4  5 6  7 8

52 µs

ON 

 1  2  3 4  5 6  7 8

4 µs

S1 DIP-switch / Description V/Y mode

ON 

 1  2  3 4  5 6  7 8

Y-mode

ON 

 1  2  3 4  5 6  7 8

V-mode

OR 

OR 

OR 

channel 1

channel 2

RS-232

If both fibre channels 1 and 2 are used 

and not redundant ring focal point

If only fibre channel 1 is used or 

if redundant ring focal point

If only fibre channel 2 is used 

channel 1

channel 1

channel 1

channel 2

RS-232

RS-232

RS-232

channel 2

channel 2

OR  

For applications that only require half duplex communication it is recommended to use 
Y-mode. Please see the ODW-720 Management Guide for further details.

Summary of Contents for ODW-720-F2

Page 1: ...Westermo Teleindustri AB www westermo com User Guide 6651 2231 Industrial Converter RS 232 to Fibre Optic Link Repeater line and redundant ring ODW 720 F2 Fibre Optic Modem...

Page 2: ...cular purpose are made in relation to the accuracy and reliability or contents of this document Westermo reserves the right to revise this document or withdraw it at any time without prior notice Unde...

Page 3: ...nected to a power supply Class 1 Laser Product This unit is designed to meet the Class 1 Laser regulations However the user is warned not to look directly into fibre optical fibre port or any connecte...

Page 4: ...le protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used...

Page 5: ...cerning explosive atmospheres caused by gases vapours or mists G Ex Indicates that this unit is in conformity with relevant European Ex standard s nA Type of protection used This unit is a non sparkin...

Page 6: ...uest To Send RTS 8 Out Clear To Send CTS 9 Not connected Position Descripton Output values Rx In Receive port Max 0 dBm Tx Out Transmit port Position Descripton Input values 1 In Common Uin 10 60 VDC...

Page 7: ...it is protected from light for example daylight or light from luminaires See Installation in an apparatus cabinet above for requirements on the external apparatus cabinet Secureness of plugs When this...

Page 8: ...Title Issue EN 61000 6 1 Electromagnetic compatibility Immunity residential environments 2007 EN 61000 6 2 Electromagnetic compatibility Immunity industrial environments 2005 EN 61000 6 3 Electromagn...

Page 9: ...ltage Mains freq 50 Hz EN 61000 4 16 Signal ports 100 V 50 Hz line to earth Mains freq 50 Hz SS 436 15 03 Signal ports 250 V 50 Hz line to line Radiated emission EN 55022 Enclosure Class B FCC part 15...

Page 10: ...between electrical RS 232 and a fibre optical link ODW 720 can also be used to convert from RS 232 to RS 485 by using a ODW 720 in the same link as ODW 730 Repeater optical fibre links ODW 720 is a f...

Page 11: ...larity protected Redundant power input Yes Isolation to RS 232 and Status port Connection Detachable screw terminal Connector size 0 75 2 5 mm2 AWG 18 13 Connect the unit using at least 18 AWG 0 75 mm...

Page 12: ...system of an installation and may be directly connected to the protective earth Optical Power Budget The allowed link length is calculated from the optical power budget OPB the available optical power...

Page 13: ...310 Tx1310 Rx 1550 Tx 1550 Rx 1310 Transmitter Output optical power min max 8 0 dBm 14 8 dBm Receiver Input sensitivity max 34 dBm 32 dBm Receiver Input optical power max 3 dBm 0 dBm Optical power bud...

Page 14: ...D 3 In Transmitted Data TD 4 Not connected 5 Signal Ground SG 6 Out Data Set Ready DSR 7 In Request To Send RTS 8 Out Clear To Send CTS 9 Not connected RS 232 D sub Status screw terminal Position Desc...

Page 15: ...ablished at CH 1 OFF No optical power detected and no link to other unit has been established at CH 1 TD Flash Data received on the electrical interface and transmitted out on the optical inter face O...

Page 16: ...ON 1 2 3 4 5 6 7 8 1200 bit s ON 1 2 3 4 5 6 7 8 57 6 kbit s ON 1 2 3 4 5 6 7 8 9 bits data format ON 1 2 3 4 5 6 7 8 2400 bit s ON 1 2 3 4 5 6 7 8 115 2 kbit s ON 1 2 3 4 5 6 7 8 10 bits data format...

Page 17: ...s ON 1 2 3 4 5 6 7 8 4 s S1 DIP switch Description V Y mode ON 1 2 3 4 5 6 7 8 Y mode ON 1 2 3 4 5 6 7 8 V mode OR OR OR channel 1 channel 2 RS 232 If both fibre channels 1 and 2 are used and not red...

Page 18: ...multaneously ON 1 2 3 4 5 6 7 8 Redundant ring mode ON 1 2 3 4 5 6 7 8 Set status port on both local fibre link FL L and remote fibre link FL R errors ON 1 2 3 4 5 6 7 8 Multidrop mid unit or Redundan...

Page 19: ...lay witch may be used to trigger an external alarm if a fault condition occurs During normal operation pins 1 and 2 are in contact with each other and pins 2 and 3 are isolated During an optical link...