7
Note
1:
It
is
a
good
practice
to
turn
off
input
and
load
power.
Otherwise,
your
screwdriver
blade
can
inadvertently
short
your
terminal
connections
to
the
grounded
enclosure.
Note
2:
The
range
of
the
suitable
electric
wire
is
from
12
to
22
AWG.
Note
3:
The
unit
will
alarm
for
loss
of
power,
for
instance,
PSU,
DC1
or
DC2.
2.3
Power
Supply
Specifications
Power
Supply
Type
Input
Range
Fuse
Rating
Max.
Power
Consumption
Min
Max
All
Ethernet
Ports
48
VDC
46
VDC
57
VDC
10A(T)
28
0
W
HI
(250
VDC)
HI
(110/230
VAC)
127
VDC
90
VAC
370
VDC
264
VAC
4A(T)
Table:
Power
Supply
Specifications
MRI
‐
128
‐
F4G
‐
PSE/24
Power
Supply
Type
Input
Range
Fuse
Rating
Power
Consumption
Min
Max
Worst
Case
Max
48
VDC
46
VDC
57
VDC
1.5A(F)
369.6W
369.6W
53
VDC
52
VDC
57
VDC
1.5A(F)
568W
720W
MRI
‐
128
‐
F4G
‐
PSE/16
Power
Supply
Type
Input
Range
Fuse
Rating
Power
Consumption
Min
Max
Worst
Case
Max
48
VDC
46
VDC
57
VDC
1.5A(F)
246.4W
246.4W
53
VDC
52
VDC
57
VDC
1.5A(F)
364W
480W