background image

3.4. Connector Information

3.4.1. DC Power Connection

Illustration

Position

Product marking

Direction

Description

2

1

1

-

Input

Common

2

+

Input

Supply voltage input DC

Table 4. Power input

3.4.2. Ethernet
The Ethernet ports are on the front of the unit and are marked LAN 1 and LAN 2. Each
port has a LED indicating the connection speed and a LED indicating activity. Both ports
are capable of auto-negotiation, meaning cross-over cables are not required. The Ethernet
ports are switched, allowing more than one Ethernet device to be connected to the unit at
one time.

1

2

No.

Description

No.

Description

1

Activity LED

2

Connection speed LED

Illustration

Pin no. 

Signal

Direction

Description

1

TD+

In/Out

Transmitted/Received data

2

TD-

In/Out

Transmitted/Received data

3

RD+

In/Out

Transmitted/Received data

4

-

-

Not connected

5

-

-

Not connected

6

RD-

In/Out

Transmitted/Received data

7

-

-

Not connected

8

-

-

Not connected

Table 5. Ethernet TX connections (RJ-45 connector), LAN 1-2

10

MRD-415 and MRD-455

Summary of Contents for MRD-415

Page 1: ...www westermo com MRD 415 and MRD 455 Industrial Cellular Router ...

Page 2: ...roduct Description 8 3 2 Available Models MRD 9 3 3 Hardware Overview 9 3 3 1 Hardware Overview 9 3 4 Connector Information 10 3 4 1 DC Power Connection 10 3 4 2 Ethernet 10 3 4 3 Serial Port DCE Female 11 3 5 LED Indicators 11 3 6 Dimensions 12 4 Installation 13 4 1 Mounting 13 4 2 Power Supply 13 4 3 Antennas 13 4 4 Protective Earth Connection 13 4 5 Cooling 14 4 6 Installing the SIM Card 14 4 7...

Page 3: ... the Westermo products It includes information on safety and regulations a product description installation instructions and technical specifications 1 3 Software Tools Related software tools are available at www westermo com support software tools 1 4 License and Copyright for Included FLOSS This product includes software developed by third parties including Free Libre Open Source Software FLOSS ...

Page 4: ...ardous situation Possible death or major injury Major damage to the product CAUTION Indicates a potentially hazardous situation Minor or moderate injury Moderate damage to the product NOTICE Provides information in order to avoid misuse of the product confusion or misunderstanding No personal injury Minor damage to the product NOTE Used for highlighting general but important information No persona...

Page 5: ...e personnel only During installation ensure a protective earthing conductor is first connected to the protective earthing terminal only valid for metallic housings Westermo recommends a cross sectional area of at least 4 mm2 Upon removal of the product ensure that the protective earthing conductor is disconnected last HAZARDOUS VOLTAGE Do not open an energised product Hazardous voltage may occur w...

Page 6: ... below to maintain full operation of the product and to fulfill the warranty obligations Do not drop knock or shake the product Rough handling above the specification may cause damage to internal circuit boards Use a dry or slightly water damp cloth to clean the product Do not use harsh chemicals cleaning solvents or strong detergents Do not paint the product Paint can clog the product and prevent...

Page 7: ...ds Certifications CE according to RED 2014 53 EU RoHS EMC EN 301489 1 EN 301489 19 EN 301489 52 Safety EN 50385 EN 62311 Radio spectrum usage EN 301908 1 EN 301908 2 EN 301908 13 Shock and vibration EN 61373 2 5 2 Simplified Declaration of Conformity Hereby Westermo declares that this product is in compliance with applicable EU directives and UK legislations The full declaration of conformity and ...

Page 8: ...ction maintenance and network to network roaming ensures a very high availability and connection that is always available Which is crucial in mission critical installations where even the shortest downtime can prove very costly The MRD 415 comes in a very slim and robust casing which is ideal for wall mounting in small spaces taking up very little space in a cabinet or similar Connections come out...

Page 9: ...Overview 3 3 1 Hardware Overview MRD 415 2 1 3 4 3 6 7 1 4 2 6 7 8 8 5 5 No Description 1 SIM card drawer s 2 Protective Earth 3 Antenna connectors 3 pcs 4 Power connector 5 Ethernet TX ports 6 Factory reset switch 7 LED indicators 8 Serial port Table 3 Location of interface ports and LED indicators MRD 415 and MRD 455 9 ...

Page 10: ...auto negotiation meaning cross over cables are not required The Ethernet ports are switched allowing more than one Ethernet device to be connected to the unit at one time 1 2 No Description No Description 1 Activity LED 2 Connection speed LED Illustration Pin no Signal Direction Description 1 TD In Out Transmitted Received data 2 TD In Out Transmitted Received data 3 RD In Out Transmitted Received...

Page 11: ...s LED Status Description STS Status RED No wireless network has been detected RED FLASH A wireless network has been detected GREEN Power up self test OK no issues NET NET 1 NET 2 Network indicator OFF Not ready RED RF circuitry initialising or network registration fault GREEN RED Network connection fault GREEN FLASH Searching for network GREEN Locked to network GREEN 1 BLINK Signal strength indica...

Page 12: ...mensions Dimensions are stated in mm 124 33 3 10 4 15 154 2 40 40 103 135 142 50 R8 R8 R4 22 3 Figure 3 Dimensional drawing MRD 415 92 10 36 103 53 Figure 4 Dimensional drawing MRD 455 12 MRD 415 and MRD 455 ...

Page 13: ...designed to self protect from permanent damage if the voltage exceeds 60 VDC or if reverse polarity is applied The product may need to be returned for service if this occurs The product can also be damaged if there is any potential difference between the chassis ground RS 232 signal ground power input or antenna shield Before connecting any wiring ensure all components are earthed to a common grou...

Page 14: ... inches left right of the product is recommended The product should be mounted in a clean and dry location protected from water excessive dust corrosive fumes extremes of temperature and direct sunlight Allow sufficient ventilation to ensure adequate cooling of the product 10mm 10mm Figure 7 Miminum spacing of product 4 6 Installing the SIM Card 1 To eject the SIM card drawer press the SIM card ej...

Page 15: ... to view the web pages a computer with a fixed IP address on the same sub net as the product will need to be connected to one of the LAN ports The default IP settings of the product are IP Address 192 168 2 200 Netmask 255 255 255 0 Note The DHCP server of the unit is by default disabled 4 7 1 Accessing the MRD 1 Open a web browser on the PC and browse to http 192 168 2 200 the default MRD IP addr...

Page 16: ...ation 1 Power down the unit 2 Use a suitable tool and depress the reset switch 3 Power up the unit ensuring the switch remains depressed for approximately 10 seconds after power is applied The STS LED and NET LED will flash twice to indicate a reset 4 The router will now re boot as normal with the factory default settings NOTE Using the Factory default reset switch will erase all existing configur...

Page 17: ...v2 VRRP GRE Stateful inspection Firewall ACL NAT Port Forwarding 25 x IPsec VPN PSK and X 509a 1 x L2TP client 1 x PPTP client 1 x OpenVPN SSL VPN client RADIUS PPP Dial in Dial out Manageability Management tools web interface HTTP and HTTPS Command Line Interface CLI via SSHv2 and TELNET SNMPv1 v2c v3 SMS Control Flexible alarm event handling system Syslog log files and remote syslog server SNTP ...

Page 18: ...le for MRD 455 Ethernet TX Electrical specification IEEE std 802 3 Data rate 10 Mbit s 100 Mbit s auto Duplex Full or half auto Circuit type SELV Transmission range 100 m 328 ft Isolation All other ports Connection RJ 45 auto MDI MDI X Cabling Shielded cable is not required except when installed in railway applications as signalling and telecommunications apparatus and located close to railsa Cond...

Page 19: ...orithm Circuit type SELV Transmission range 15 m 49 ft Connection 9 pin D sub female Shielded cable Not required Conductive chassis Yes Number of ports 1 Cellular interface MRD 415 frequency bands MHz MRD 455 frequency bands MHz 2G GSM 900 DCS 1800 GSM 900 DCS 1800 3G B1 B3 B8 B1 B5 B8 4G B2 B3 B7 B8 B20 B28A B1 B3 B5 B7 B8 B20 B38 B40 B41 Category LTE Cat 1 LTE Cat 4 MRD 415 and MRD 455 19 ...

Page 20: ...000 4 5 Signal ports MRD 415 1 kV Crit B MRD 455 2 kV Power ports MRD 415 0 5 kV Crit B MRD 455 2 kV Conducted RF immunity EN 61000 4 6 All ports 10 V 0 15 80 MHz Conducted magnetic fields EN 61000 4 8 Only MRD 455 10 A m DC voltage dips EN 61000 4 29 12 VDC and 24 VDC up to 300 ms A 1s B Radiated RF emission CISPR 16 2 3 ANSI C63 4 FCC part 15 Enclosure Class B Conducted RF emission CISPR 16 2 1 ...

Page 21: ...onal 0 95 relative humidity Storage and transport Altitude Operational 2000 m 70 kPa Service life Operational 10 years MTBF MIL 217F MRD 415 1 367 000 hours MRD 455 911 000 hours Vibration IEC 61373 Enclosure Aluminum Weight MRD 415 0 3 kg MRD 455 0 4 kg Degree of protection EN 60529 Enclosure IP40 Cooling Convection Table 9 Environmental and mechanical conditions MRD 415 and MRD 455 21 ...

Page 22: ...e description Rev H 2021 11 Westermo logo updated products MRD 315 and MRD 355 deleted from user guide new information structure throughout the manual Agency approval and standards complience EN IEC 60950 1 deleded 22 MRD 415 and MRD 455 ...

Page 23: ...Westermo Metallverksgatan 6 SE 721 30 Västerås Sweden Tel 46 16 42 80 00 Fax 46 16 42 80 01 E mail info westermo com www westermo com 6623 2250 REV H 2021 11 Westermo Network Technologies AB Sweden ...

Reviews: