background image

7

6643-2250

Description

L106-F2G/L206-F2G is an Industrial switch made for harsh enviroments. The switch can 
be used in either 100 Mbit or Gigabit networks due to our multi-rate SFP solution.  
L106-F2G/L206-F2G can also be used together with our previous Lynx-series of  
switches. Our unique FRNT
(Fast Recovery of Network Topology) technology is the fastest protocol on the market 
to re-configure a network in the event of any link or hardware failure. That is why our 
products are used in safety critical applications such as tunnels, traffic signal control and 
railway systems.
Installations in harsh environments and places with heavy electrical interference require 
the use of a reliable media. Lynx provides a number of solutions using fibre optic 
transceivers.
Multi- or singlemode transceivers can be used to build point-to-point or redundant 
ring networks with ranges up to 120 km between each switch. Our BIDI transceiver, 
which transmits and receives data on a single fibre can be used in applications where  
the number of fibre cores are limited.
Real-time properties are implemented in the switch in order to achieve determinism 
for real time critical applications. Lynx supports QoS (Quality of Service) with four 
priority queues and strict priority scheduling as well as HoL (Head of Line Blocking 
Prevention). All to assure that the data network is deterministic.

Summary of Contents for Lynx L106-F2G

Page 1: ...Westermo Teleindustri AB www westermo com User Guide 6643 2250 Industrial Ethernet 6 port Switch Lynx L106 F2G L206 F2G WeOS...

Page 2: ...ty or contents of this document Westermo reserves the right to revise this document or withdraw it at any time without prior notice Under no circumstances shall Westermo be responsible for any loss of...

Page 3: ...Surface of Equipment may exceed Touch Temperature Limit according to EN IEC UL 60950 1 To reduce the risk of fire use only No 26 AWG or larger telecommunication line cord Class 1 Laser Product Do not...

Page 4: ...telecommunications apparatus Safety UL IEC EN 60950 1 IT equipment Marine DNV GL rules for classification Ships and offshore units FCC Part 15 105 Notice This equipment has been tested and found to c...

Page 5: ...ty for industrial environments 2005 EN 61000 6 3 Electromagnetic compatibility Emission for residential environments 2007 A1 2011 EN 61000 6 4 Electromagnetic compatibility Emission for industrial env...

Page 6: ...e Class A Class A Conducted RF emission CISPR 16 2 1 ANSI C63 4 FCC part 15 Power port Class B Signal ports Class B Dielectric strength EN 60950 1 Power port to all other ports 1 5 kVrms 50 Hz 1 min S...

Page 7: ...ations in harsh environments and places with heavy electrical interference require the use of a reliable media Lynx provides a number of solutions using fibre optic transceivers Multi or singlemode tr...

Page 8: ...t type TNV 1 Transmission range Up to 150 m with CAT5e cable or better Isolation to All other Connection RJ 45 auto MDI MDI X Shielded cable Not required except when installed in Railway applications...

Page 9: ...onnector type A Console Electrical specification TTL level Data rate 115 2 kbit s Data format 8 data bits no parity 1 stop bit no flow control Circuit type SELV Connection 2 5 mm jack use only Westerm...

Page 10: ...puter USB port if drivers are needed they can be downloaded from ourWeb page 3 Use a terminal emulator and connect with correct speed and format 115200 8N1 to the assigned port For more information ab...

Page 11: ...o 1 Status Output Alarm relay status contact No 2 Status Output Alarm relay status contact No 3 Digital in Input Digital in No 4 Digital in Input Digital in The Status output is a potential free opto...

Page 12: ...1 OFF Unit has no power GREEN Power OK on DC1 RED Power failure on DC1 DC2 OFF Unit has no power GREEN Power OK on DC2 RED Power failure on DC2 FRNT OFF FRNT disabled GREEN FRNT OK RED FRNT Error BLIN...

Page 13: ...ted DIN clip Removal Cooling This unit uses convection cooling To avoid obstructing the airflow around the unit use the following spacing rules Minimum spacing 25 mm 1 0 inch above below and 10 mm 0 4...

Page 14: ...gement Tool in the WeOS management guide Factory default IP address 192 168 2 200 Netmask 255 255 255 0 Gateway Disabled Note If you are not sure about the subnet consult your network administrator Co...

Page 15: ...tory default You now have the choice to go ahead with the factory reset or to skip factory reset and boot as normal Go ahead with factory reset Acknowledge that you wish to conduct the factory reset b...

Page 16: ...r www westermo fr Germany info westermo de www westermo de North America info westermo com www westermo com Singapore sales westermo com sg www westermo com Sweden info sverige westermo se www westerm...