background image

9

6643-2250

I/O / Relay output

Maximum voltage/current

60 VDC / 80 mA

Contact resistance

Max 30 

Ω

Isolation to

All other

Connection

Detachable screw terminal

Connector size

0.2 – 2.5 mm

2

 (AWG 24 – 12)

I

/O / Digital input

Maximum voltage/load current

60 VDC / 2 mA

Voltage levels

Logic one: >12V 
Logic zero: <1V

Isolation to

All other

Connection

Detachable screw terminal

Connector size

0.2 – 2.5 mm

2

 (AWG 24 – 12)

USB

Electrical specification

USB 2.0 host interface

Data rate

Up to 12 Mbit/s (full-speed mode)

Circuit type

SELV

Maximum supply current

500 mA

Connection

USB receptacle connector type A

Console

Electrical specification

TTL-level

Data rate

115.2 kbit/s

Data format

8 data bits, no parity, 1 stop bit, no flow control

Circuit type

SELV

Connection

2.5 mm jack, use only Westermo cable 1211-2027

SFP Transceivers

Supported transceivers

Firmware prior to 4.4.0 accepts Westermo branded
transceivers only. From 4.5.0 other transceivers are accepted with a notice and the
unit will no longer be UL approved. Temp.specifications are also depending on the
used transeivers. 

Note: 

To comply with UL60950-1 only UL recognized SFP transceivers should be used.

Deviations

With copper transceiver

 1100-0148 the specified operating temperature on Lynx  

is 0 to +50ºC (32 to +122°F).

FRNT

 reconfiguration times can not be guaranteed with copper transceivers.

Summary of Contents for Lynx L106-F2G

Page 1: ...Westermo Teleindustri AB www westermo com User Guide 6643 2250 Industrial Ethernet 6 port Switch Lynx L106 F2G L206 F2G WeOS...

Page 2: ...ty or contents of this document Westermo reserves the right to revise this document or withdraw it at any time without prior notice Under no circumstances shall Westermo be responsible for any loss of...

Page 3: ...Surface of Equipment may exceed Touch Temperature Limit according to EN IEC UL 60950 1 To reduce the risk of fire use only No 26 AWG or larger telecommunication line cord Class 1 Laser Product Do not...

Page 4: ...telecommunications apparatus Safety UL IEC EN 60950 1 IT equipment Marine DNV GL rules for classification Ships and offshore units FCC Part 15 105 Notice This equipment has been tested and found to c...

Page 5: ...ty for industrial environments 2005 EN 61000 6 3 Electromagnetic compatibility Emission for residential environments 2007 A1 2011 EN 61000 6 4 Electromagnetic compatibility Emission for industrial env...

Page 6: ...e Class A Class A Conducted RF emission CISPR 16 2 1 ANSI C63 4 FCC part 15 Power port Class B Signal ports Class B Dielectric strength EN 60950 1 Power port to all other ports 1 5 kVrms 50 Hz 1 min S...

Page 7: ...ations in harsh environments and places with heavy electrical interference require the use of a reliable media Lynx provides a number of solutions using fibre optic transceivers Multi or singlemode tr...

Page 8: ...t type TNV 1 Transmission range Up to 150 m with CAT5e cable or better Isolation to All other Connection RJ 45 auto MDI MDI X Shielded cable Not required except when installed in Railway applications...

Page 9: ...onnector type A Console Electrical specification TTL level Data rate 115 2 kbit s Data format 8 data bits no parity 1 stop bit no flow control Circuit type SELV Connection 2 5 mm jack use only Westerm...

Page 10: ...puter USB port if drivers are needed they can be downloaded from ourWeb page 3 Use a terminal emulator and connect with correct speed and format 115200 8N1 to the assigned port For more information ab...

Page 11: ...o 1 Status Output Alarm relay status contact No 2 Status Output Alarm relay status contact No 3 Digital in Input Digital in No 4 Digital in Input Digital in The Status output is a potential free opto...

Page 12: ...1 OFF Unit has no power GREEN Power OK on DC1 RED Power failure on DC1 DC2 OFF Unit has no power GREEN Power OK on DC2 RED Power failure on DC2 FRNT OFF FRNT disabled GREEN FRNT OK RED FRNT Error BLIN...

Page 13: ...ted DIN clip Removal Cooling This unit uses convection cooling To avoid obstructing the airflow around the unit use the following spacing rules Minimum spacing 25 mm 1 0 inch above below and 10 mm 0 4...

Page 14: ...gement Tool in the WeOS management guide Factory default IP address 192 168 2 200 Netmask 255 255 255 0 Gateway Disabled Note If you are not sure about the subnet consult your network administrator Co...

Page 15: ...tory default You now have the choice to go ahead with the factory reset or to skip factory reset and boot as normal Go ahead with factory reset Acknowledge that you wish to conduct the factory reset b...

Page 16: ...r www westermo fr Germany info westermo de www westermo de North America info westermo com www westermo com Singapore sales westermo com sg www westermo com Sweden info sverige westermo se www westerm...

Reviews: