Maintenance

No maintenance is required, as long as the unit is used as intended within the specified 
conditions.

Agency approvals and standards compliance

Type

Approval / Compliance

EMC

EN 61000-6-1, Immunity residential environments
EN 61000-6-2, Immunity industrial environments
EN 61000-6-3, Emission residential environments
EN 61000-6-4, Emission industrial environments
EN 55022 +A1, Emission IT equipment
EN 55024 +A1 + A2, Immunity IT equipment
FCC part 15 Class B
EN 50121-4, Railway signalling and telecommunications apparatus
IEC 62236-4, Railway signalling and telecommunications apparatus

Safety

UL/IEC/EN 60950-1, IT equipment

Marine

DNV Standard for Certification no. 2.4

Ex

EN 60079-0, EN 60079-15 and EN 60079-28

FCC Part 15.105  
Notice:

This equipment has been tested and found to comply with the limits for a Class B digital 
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide 
reasonable protection against harmful interference in a residential installation. This 
equipment generates, uses and can radiate radio frequency energy and, if not installed 
and used in accordance with the instructions, may cause harmful interference to radio 
communications. However, there is no guarantee that interference will not occur in a 
particular installation. If this equipment does cause harmful interference to radio or 
television reception, which can be determined by turning the equipment off and on, the 
user is encouraged to try to correct the interference by one or more of the following 
measures:
… Reorient or relocate the receiving antenna
… Increase the separation between the equipment and receiver
… Connect the equipment into an outlet on a circuit different from that to which the 

receiver is connected

… Consult the dealer or an experienced radio/TV technician for help.

Corrosive  
environment 

Notice:

This product has been successfully tested in a corrosion test according to  
IEC 60068-2-60, method 3. This means that the product meets the requirements  
to be placed in an environment classified as ISA-S71.04 class G3.
Note!  If the product is placed in a corrosive environment, it is important that all  
un-used connector sockets are protected with a suitable plug in order to avoid  
corrosion attacks on the gold plated pins in connectors.

Summary of Contents for L106-S2 EX

Page 1: ...Westermo Teleindustri AB www westermo com User Guide 6643 22701 Industrial Ethernet 8 port Device Server Switch Lynx DSS L108 F2G S2 EX L208 F2G S2 EX WeOS...

Page 2: ...the OpenSSL Project for use in the OpenSSL Toolkit http www openssl org Legal information The contents of this document are provided as is Except as required by applicable law no warranties of any ki...

Page 3: ...lies with the relevant requirements of EN 60079 0 and EN 60079 15 All external connections to the equipment and where applicable the SFP modules must not be inserted or removed unless either the area...

Page 4: ...ultimode BiDi 2 km 1310 nm TX 1550 nm RX 1100 0153 MLC2 BiDi B Multimode BiDi 2 km 1550 nm TX 1310 nm RX SFP Transceivers 1 Gbit 1100 0144 GMLC550 SX Multimode LC Connector 550 m 850 nm SX 1100 0147 G...

Page 5: ...N 60079 0 und EN 60079 15 erf llt installiert werden Alle u eren Anschl sse des Ger tes und auch die SFP Module d rfen nur dann verbunden oder getrennt werden wenn entweder der Bereich in dem das Ger...

Page 6: ...A Multimode BiDi 2 km 1310 nm TX 1550 nm RX 1100 0153 MLC2 BiDi B Multimode BiDi 2 km 1550 nm TX 1310 nm RX SFP Transceiver 1 Gbit 1100 0144 GMLC550 SX Multimode LC Anschluss 550 m 850 nm SX 1100 0147...

Page 7: ...icables EN 60079 0 et EN 60079 15 Toutes les connexions externes l quipement et le cas ch ant les modules SFP ne doivent pas tre ins r s ou retir s sauf si la zone dans laquelle l quipement est instal...

Page 8: ...i A multimode Bi Di 2 km 1310 nm TX 1550 nm RX 1100 0153 MLC2 BiDi B multimode Bi Di 2 km 1550 nm TX 1310 nm RX Transmetteurs SFP 1 Gbit 1100 0144 GMLC550 SX multimode connecteur LC 550 m 850 nm SX 11...

Page 9: ...and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that inter...

Page 10: ...compatibility Immunity for industrial environments 2005 EN 61000 6 3 Electromagnetic compatibility Emission for residential environments 2007 EN 61000 6 4 Electromagnetic compatibility Emission for i...

Page 11: ...on IT equipment EN 55024 A1 A2 Immunity IT equipment FCC part 15 Class B EN 50121 4 Railway signalling and telecommunications apparatus IEC 62236 4 Railway signalling and telecommunications apparatus...

Page 12: ...safe distance Standard compass 5 4 H deviation 15 cm Steering standby steering emergency compass 18 H deviation 10 cm Safety Safety UL IEC EN 60950 1 IT equipment EN 60950 1 dielectric strength Power...

Page 13: ...nrush current 22 7 10 3 A s 48 VDC Startup current 2 x Rated current Polarity Reverse polarity protected Redundant power input Yes Isolation to All other Connection Detachable screw terminal Connector...

Page 14: ...nection RJ 45 according to EIA 561 Shielded cable Recommended Conductive housing Yes Number of ports 1 Interface specifications RS 422 485 Electrical specification Configurable for EIA RS 232 or EIA R...

Page 15: ...ole Electrical specification LVTTL LVCMOS level Data rate 115 2 kbit s Data format 8 data bits no parity 1 stop bit no flow control Circuit type SELV Connection 2 5 mm jack use only Westermo cable 121...

Page 16: ...ription Input output values No 1 TD In Out Transmitted Received data Per port U 1 V 4 V s I 20 mA Data rate 10 100 Mbit s No 2 TD In Out Transmitted Received data No 3 RD In Out Transmitted Received d...

Page 17: ...ceive U 5 V max I 250 mA max Data rate 50 bit s 2 Mbit s No 2 T T R Out In RS 422 Transmit RS 485 Transmit Receive No 3 R In RS 422 Receive No 4 Not used No 5 Not used No 6 R In RS 422 Receive No 7 No...

Page 18: ...ermo cable 1211 2027 2 Connect cable to your computer USB port if drivers are needed they can be downloaded from ourWeb page 3 Use a terminal emulator and connect with correct speed and format 115200...

Page 19: ...Alarm relay status contact Iin 80 mA max No 3 Digital in Input Digital in Uin 60 VDC max No 4 Digital in Input Digital in Iin 2 mA max The Status output is a potential free opto isolated normally clos...

Page 20: ...2 OFF Unit has no power GREEN Power OK on DC2 RED Power failure on DC2 FRNT OFF FRNT disabled GREEN FRNT OK RED FRNT Error BLINK Unit configured as FRNT Focal Point RSTP OFF RSTP disabled GREEN RSTP e...

Page 21: ...ted DIN clip Removal Cooling This unit uses convection cooling To avoid obstructing the airflow around the unit use the following spacing rules Minimum spacing 25 mm 1 0 inch above below and 10 mm 0 4...

Page 22: ...entation is available in the chapter The Command Line Management Tool in the WeOS management guide Factory default IP address 192 168 2 200 Netmask 255 255 255 0 Gateway Disabled Note If you are not s...

Page 23: ...lt You now have the choice to go ahead with the factory reset or to skip factory reset and boot as normal Go ahead with factory reset Acknowledge that you wish to conduct the factory reset by unpluggi...

Page 24: ...e infos westermo fr www westermo fr Germany info westermo de www westermo de North America info westermo com www westermo com Singapore sales westermo com sg www westermo com Sweden info sverige weste...

Reviews: