12
6643-22701
EN 61000-4-9,
pulsed magnetic field
300 A/m
EN 61000-4-3,
radiated RF immunity
20 V/m @ (80 – 2700) MHz
1 kHz sine, 80% AM
EN 61000-4-6,
conducted RF immunity
Power port: 10 V, 80% AM, 1 kHz; (0.15 – 80) MHz
Ethernet: 10 V, 80% AM, 1 kHz; (0.15 – 80) MHz
Ethernet: 10 V, 80% AM, 1 kHz; (0.15 – 80) MHz
Status out/Digital in: 10 V, 80% AM, 1 kHz; (0.15 – 80) MHz
Status out/Digital in: 10 V, 80% AM, 1 kHz; (0.15 – 80) MHz
Serial ports: 10 V, 80% AM, 1 kHz; (0.15 – 80) MHz
Earth port: 10 V, 80% AM, 1 kHz; (0.15 – 80) MHz
EN 55022,
radiated RF emmision,
FCC Part 15/ DNV 2.4
EN 55022/FCC Part 15/DNV 2.4, Class B / DNV bridge
EN 55022,
conducted RF emmision,
EN 55022/FCC Part 15/DNV 2.4, Class B / DNV bridge
DNV 2.4,
compass safe distance
Standard compass (5.4°/H deviation) = 15 cm
Steering/standby steering/emergency compass
(18°/H deviation) = 10 cm
Safety
Safety
UL/IEC/EN 60950-1, IT equipment
EN 60950-1,
dielectric strength
Power port to all other ports: 1.5 kVrms, 50 Hz, 1 min
Ethernet ports to all other ports: 1.5 kVrms, 50 Hz, 1 min
RS-232 port to all other ports: 1.5 kVrms, 50 Hz, 1 min
RS-422/485 port to all other ports: 1.5 kVrms, 50 Hz, 1 min
Reliability prediction
MTBF, operating
517 000 hours
Service life, operating
10 years
Climatic
Temperature, operating
–40 to +70°C (–40 to +158°F)
Temperature, storage
–50 to +85°C (–58 to +185°F)
Humidity, operating
5 to 95 % relative humidity
Humidity, storage
5 to 95 % relative humidity
Enclosure
Enclosure
Fire enclosure
Dimensions (W x H x D)
52.5 x 100 x 101 mm
Weight
0.7 kg
Degree of protection
IP 40
Cooling
Convection
Mounting
Horizontal on 35 mm DIN-rail