3.5. LED Indicators

LED

Status

Description

ON

OFF

Product has no power

GREEN

All OK, no alarm condition

RED

Alarm condition, or until product has started
up. (Alarm conditions are configurable, see
WeOS user documentation

BLINK

Location indicator ("Here I am!"). Activated
when connected to WeConfig tool, or upon
request from web or/and CLI. RED BLINK
during boot indicates pending cable factory
reset.

RSTP/
USR1

Configurable, see WeOS user Guide

FRNT

OFF

FRNT disabled

GREEN

FRNT OK

RED

FRNT error

BLINK

Product configured as FRNT focal point

DC1

OFF

Product has no power

GREEN

Power OK on DC1

RED

+DC1 input voltage is below operating
voltage limit

DC2

OFF

Product has no power

GREEN

Power OK on DC2

RED

+DC2 input voltage is below operating
voltage limit

USR2

Configurable, see WeOS user Guide

TX/FX
ports

OFF

No link

GREEN

Link established

GREEN
FLASH

Data traffic indication

YELLOW

Port alarm and no link. Or if FRNT or RSTP
mode, port is blocked. 

Table 5. LED indicators

14

Lynx 5600 Series

Summary of Contents for 3643-0400

Page 1: ...www westermo com OS Lynx 5600 Series Industrial Gigabit switch...

Page 2: ...N 61000 6 5 Notice 8 2 5 5 Corrosive Environment 8 2 5 6 Simplified Declaration of Conformity 9 3 Product Description 10 3 1 Product Description 10 3 2 Available Models 10 3 3 Hardware Overview 11 3 4...

Page 3: ...d users of the Westermo products It includes information on safety and regulations a product description installation instructions and technical specifications 1 3 Software Tools Related software tool...

Page 4: ...zardous situation Possible death or major injury Major damage to the product CAUTION Indicates a potentially hazardous situation Minor or moderate injury Moderate damage to the product NOTICE Provides...

Page 5: ...Replacing the internal fuse must only be performed by Westermo qualified personell WARNING POWER SUPPLY CONNECTION There are safety regulations on which power sources that shall be used in conjunctio...

Page 6: ...ed the same way CAUTION CORROSIVE GASES If the product is placed in a corrosive environment it is important that all unused connector sockets are protected with a suitable plug in order to avoid corro...

Page 7: ...correctly you will help to reduce hazardous substances and prevent potential negative consequences to both environment and human health which could be caused by inappropriate disposal Figure 1 WEEE s...

Page 8: ...sult the dealer or an experienced radio TV technician for help 2 5 3 IEC 61850 3 Notice This product has been tested according to IEC 61850 3 Standalone this product meets the requirements stated in t...

Page 9: ...declares that this product is in compliance with applicable EU directives The full EU declaration of conformity and other detailed information is available at www westermo com support product support...

Page 10: ...ndustrial grade components are used which contributes towards a market leading mean time between failure MTBF maximized service life and reduced operational and life cycle costs By providing full giga...

Page 11: ...tion No Description 1 Gigabit ports 2 Console port 3 Micro SD 4 Label with QR codea 5 Gigabit SFP Ports 6 Protective earth terminal 7 Power Input and I O connection 8 Warning symbol see warning in Pow...

Page 12: ...Unit condition Status NO C Unpowered pre operational or Alarm active OPEN Operational and Alarm inactive CLOSED Table 4 I O connection status output WARNING POWER SUPPLY CONNECTION There are safety re...

Page 13: ...ivers are supplied with plugs to avoid contamination inside the optical port They are very sensitive to dust and dirt If the fibre is disconnected from the product the protective plugs on the transmit...

Page 14: ...t RSTP USR1 Configurable see WeOS user Guide FRNT OFF FRNT disabled GREEN FRNT OK RED FRNT error BLINK Product configured as FRNT focal point DC1 OFF Product has no power GREEN Power OK on DC1 RED DC1...

Page 15: ...3 6 Dimensions Dimensions are stated in mm and are regardless model 2 to 8 11 26 100 2 to 8 70 92 DIN surface to front 5 32 108 Figure 6 Dimensional drawing Lynx 5600 Series 15...

Page 16: ...port pin 2 Then place the product on to the DIN rail First the upper part then the lower part of the product 3 Lastly push the support pin forward to lock the product to the DIN rail Make sure the pro...

Page 17: ...t by pushing the support pin Figure 9 Removal of product with screwdriver 4 3 Earth Connection For correct function the earth connection needs to be properly connected to a solid ground See the figure...

Page 18: ...rflow around the unit use the following spacing rules Minimum spacing 25 mm 1 0 inch above below and 10 mm 0 4 inches left right the unit Spacing is recommended for the use of unit in full operating t...

Page 19: ...Reverse polarity protected Redundant power input Yes Isolation All other ports Connector Detachable push in terminal Conductor cross section flexible 0 2 1 5 mm AWG 24 16 Stripping length cable 10 mm...

Page 20: ...cross section 0 2 1 5 mm AWG 24 16 Stripping length cable 10 mm Circuit type SELV Maximum voltage current 60 VDC 80 mA aExternal circuits connected to I O connectors shall be SELV rated circuits galva...

Page 21: ...ceiver supported Console porta Electrical specification USB 2 0 device interface Data rate Up to 480 Mbps high speed mode Circuit type SELV Maximum supply current 100 mA Connector USB Micro B connecto...

Page 22: ...2 Direct on shield 1 2 50 s Power frequency magnetic field EN 61000 4 8 Enclosure 300 A m continues DC 16 7 50 60 Hz 1000 A m 10 s 50 60 Hz Pulsed magnetic field EN 61000 4 9 Enclosure 300 A m Damped...

Page 23: ...m PM 200 Hz square at 900 MHz Conducted RF immunity EN 61000 4 6 AC power porta 10 V m 0 15 to 80 MHz spot freq 2 3 4 6 2 8 2 12 6 16 5 18 8 22 25 MHz DC power port Ethernet ports I O port Earth port...

Page 24: ...ielectric strength IEC 60255 27 AC power port to secondary DC sidea 2000 VAC rms 60 s Power port DC to all other ports 1500 VAC rms 60 s I O port to all other ports IEEE 802 3 Ethernet ports to all ot...

Page 25: ...ionc IEC 60068 2 6 sine Operational 5 to 20 Hz 1 3 mm 20 to 200 Hz 1 g 20 sweep cycles in each axis 1 octave min Class 2 10 to 150 Hz at 2 g 20 sweep cycles in each axis 1 octave min 5 to 8 Hz at 7 5...

Page 26: ...IEC 61010 1 Indoor aRefer to Safety and Regulations chapter regarding touch temperature bMethod 3 21 days corresponds to Harsh Industrial Environment G3 which is defined in ANSI ISA 17 04 2015 cThe p...

Page 27: ...7 Revision Notes Revision Date Change description Rev A 2020 09 First revision Lynx 5600 Series 27...

Page 28: ...Westermo SE 635 35 Stora Sundby Sweden Tel 46 16 42 80 00 Fax 46 16 42 80 01 E mail info westermo com www westermo com 6643 25002 REV A 2020 09 Westermo Network Technologies AB Sweden...

Reviews: