Ibex-RT-310 and Ibex-RT-320 Series User Guide
Westermo Network Technologies
17
3.5
LED Indicators
LED
Description
DC
Power status
OPR
Operation status
ERR
Error status
X1
Ethernet status for X1 port
X2
Ethernet status for X2 port
Table 7 LED Indication
NOTE
Refer to management guide for detailed LED status indication.
3.6
Factory Reset
To reset the product into factory default settings, a reset adapter is needed which is plugged into one
of the Ethernet ports X1 or X2 during startup.
Art. no.
Description
3623-0799
Factory Reset Plug, X-coded
Table 8 Factory reset plug
3.6.1
Factory Reset Procedure
Step
Description
1
Plug the factory reset adapter to one of the Ethernet interfaces
2
Power the product
3
Wait until factory reset adapter is detected. This is indicated by
solid ORANGE OPR LED and RED ERR LED
4
Remove factory reset adapter within 15 seconds
5
Successful initiation of the factory reset is indicated by blinking
ORANGE OPR LED and RED ERR LED
Table 9 Factory reset procedure
3.7
Dimensions
Dimensions are stated in mm and are regardless variants.