background image

Section DSA-WM2-140-202

030-101674 Rev. A

R

12

0803I2RA

Sl t

D

i ti

56-Pin

DNI

RJ48 Connector

Slot

#

Description

DNI

Connector

RJ48C

Label - Pin #

RJ48H

Label - Pin #

1

R1

15

J1 - 1

J15 - 1

T1

5

J1 - 2

J15 - 26

R

49

J1 - 4

J16 - 1

T

55

J1 - 5

J16 - 26

2

R1

15

J2 - 1

J15 - 2

T1

5

J2 - 2

J15 - 27

R

49

J2 - 4

J16 - 2

T

55

J2 - 5

J16 - 27

3

R1

15

J3 - 1

J15 - 3

T1

5

J3 - 2

J15 - 28

R

49

J3 - 4

J16 - 3

T

55

J3 - 5

J16 - 28

4

R1

15

J4 - 1

J15 - 4

T1

5

J4 - 2

J15 - 29

R

49

J4 - 4

J16 - 4

T

55

J4 - 5

J16 - 29

5

R1

15

J5 - 1

J15 - 5

T1

5

J5 - 2

J15 - 30

R

49

J5 - 4

J16 - 5

T

55

J5 - 5

J16 - 30

6

R1

15

J6 - 1

J15 - 6

T1

5

J6 - 2

J15 - 31

R

49

J6 - 4

J16 - 6

T

55

J6 - 5

J16 - 31

7

R1

15

J7 - 1

J15 - 7

T1

5

J7 - 2

J15 - 32

R

49

J7 - 4

J16 - 7

T

55

J7 - 5

J16 - 32

8

R1

15

J8 - 1

J15 - 8

T1

5

J8 - 2

J15 - 33

R

49

J8 - 4

J16 - 8

T

55

J8 - 5

J16 - 33

9

R1

15

J9 - 1

J15 - 9

T1

5

J9 - 2

J15 - 34

R

49

J9 - 4

J16 - 9

T

55

J9 - 5

J16 - 34

10

R1

15

J10 - 1

J15 - 10

T1

5

J10 - 2

J15 - 35

R

49

J10 - 4

J16 - 10

T

55

J10 - 5

J16 - 35

11

R1

15

J11 - 1

J15 - 11

T1

5

J11 - 2

J15 - 36

R

49

J11 - 4

J16 - 11

T

55

J11 - 5

J16 - 36

12

R1

15

J12 - 1

J15 - 12

T1

5

J12 - 2

J15 - 37

R

49

J12 - 4

J16 - 12

T

55

J12 - 5

J16 - 37

13

R1

15

J13 - 1

J15 - 13

T1

5

J13 - 2

J15 - 38

R

49

J13 - 4

J16 - 13

T

55

J13 - 5

J16 - 38

14

R1

15

J14 - 1

J15 - 14

T1

5

J14 - 2

J15 - 39

R

49

J14 - 4

J16 - 14

T

55

J14 - 5

J16 - 39

Table 3.     Customer Interface Connections

7.2

Repair and Return

Westell will repair or replace any defective Westell equipment
without cost during the warranty period if the unit is defective
for any reason other than abuse, improper use, or improper
installation. To return defective equipment, first request a Re-
turn Material Authorization (RMA) number from Westell by
calling or using one of the options shown below. Once an RMA
number is obtained, return the defective unit (freight prepaid),
along with a brief problem description, to the address we will
provide to you when you contact us.

Voice: (630) 375-4211
email: [email protected]

Replacements are shipped in the fastest manner consistent
with the situation urgency. Westell continues to repair/replace
faulty equipment beyond the warranty period for a nominal
charge.

8.

SPECIFICATIONS

The electrical and physical specifications are shown in Table 4.
To order units, call the number shown in Paragraph 6.1 and spec-
ify the enclosure ordering information shown in Table 5.

Feature

U.S.

Metric

Height

12.6 in.

32 cm

Width

12.0 in.

30.5 cm

Depth

8.8 in.

22.4 cm

Weight (approx.)

20 lb.

9 Kg

Indoor Operating Temp.

0

°

 to 122

°

F

-18

°

 to +50

°

C

Outdoor Operating Temp.

-40

°

 to 149

°

F

-40

°

 to +65

°

C

Humidity

0 to 95% (non-condensing)

Ventilation

Refer to Paragraph 3.1.3.

Input Power

Local Power. -42 to -56 VDC fused at 2 Amp, span
line power, or optional power supply, model 2555
Issue 2, 115 VAC input, -48 VDC 2.0 A output.

CI Provisioning

14 RJ C" or 2 H" jacks.

Table 4.    Physical Specifications

Part Number

Description

DSAWM-214ALCI2

CLEI* Code:
NCMD9YP3RA.
Barcode: 431784

14-circuit, digital wall-mount enclosure, locking front
door,

 

Telco Termination module, Network connections

via wirewrap pins or (2) 50-pin male Amphenol connect-
ors, Customer connections via RJ48H 50-pin female
connectors or 14 RJ48C jacks.

Options

2555I2

CLEI: PWPQATE1AA

2555 Issue 2 Optional plug-in power supply, 115 VAC in-
put to-48 VDC 2.0 Amp output,

 8’ male AC cord (wall plug)

2555I1

CLEI: PWPQK051AA

2555 Issue 1 Optional plug-in power supply, 115 VAC
input to-48 VDC 2.0 Amp output, 8’ male AC cord (wall
plug) plus 1’ female power cord receptacle

080-500455

Relay-rack-mounting kit for 19" or 23" racks

* CLEI is a trademark of Telcordia Technologies.

Table 5.    Ordering and Optioning  Information

Summary of Contents for DSAWM-214ALCI2

Page 1: ...Office CO side connections are made via wirewrap pins mounted on the plug in Telco Termination Mod ule located at the top of the enclosure or via two 50 pin Amphenol type connectors at the top rear of...

Page 2: ...ded that adequate horizontal and vertical space be left between multiple installations to allow for proper cable access and ven tilation The distance from the cable entry point should be consistent wi...

Page 3: ...nnections 3 1 2 2 Local Powering Mode When local power mode is selected TB1 on the Telco Termina tion Module provides screw terminals for 48 V battery PWR position and 48 V return PWR position A separ...

Page 4: ...ck plate from the enclosure by depressing the black metal push buttons located near the bottom on each side of the enclosure 2 Lift and place the back plate on the wall in the desired mounting locatio...

Page 5: ...om mended that spade lugs be used to connect wires to TB1 terminals Figure 7 shows the TB1 DC power and ground con nection locations Power and return ground connections can be made with stripped wire...

Page 6: ...but not factory installed for optional installation between the CHASSIS GND and CKT GND terminals on TB1 for applications re quiring chassis ground to be connected to circuit ground 3 5 2 Circuit Gro...

Page 7: ...de with stripped wire or by spade lug connectors TB1 screw position PWR is the battery return TB1 screw position CKT GND provides cir cuit ground as described in Paragraph 3 5 2 TB1 screw position CHA...

Page 8: ...access to these connections with the wirewrap pin method being the most secure requires a key for access 3 6 1 J1 J14 Connector Wirewrap Pins CO side network facility connections are typically made to...

Page 9: ...le is the following option S1 This 2 position slide switch provides a shield ground from TB1 connected to pins 7 and 8 of the RJ48C jacks J1 through J14 with S1 in the THRU position The shield ground...

Page 10: ...9 14 55 49 T R J16 Voice 800 377 8766 email global_support westell com For additional information about Westell visit the Westell World Wide Web site at http www Westell com 6 2 Part Numbers This equi...

Page 11: ...W O T1 41 4 R BR SGND 1 SGND 1 NC 2 NC 2 R 13 5 O W R 13 5 BR R T 7 6 W O T 7 6 R BR 3 R1 47 POS 3 3 G W 10 R1 47 POS 10 3 S R T1 41 4 W G T1 41 4 R S SGND 1 SGND 1 NC 2 NC 2 R 13 5 G W R 13 5 S R T 7...

Page 12: ...n the defective unit freight prepaid along with a brief problem description to the address we will provide to you when you contact us Voice 630 375 4211 email rgmdept westell com Replacements are ship...