West Mountain Radio
on.
USB Programming Instructions
Download and install the West Mountain Radio port
diagnostics utility or use another terminal program, such
as Hyper-Term. During installation, be sure to install the
drivers on the PC. The utility can be set to start every time
the PC powers up and it is always on the tool tray (lower
right) or to just run it when needed.
Open the RIGrunner 4010S+ unit. Power up the unit and
switch to the ON position. When the LED is lit on, connect
a micro-USB cable (not included with the RIGrunner)
between the RIGrunner 4010S+ and the PC. The first time,
Windows will attempt to install the driver. If the diagnostic
utility was previously installed, Windows should find the
driver on its own. Now the Yellow LED should be rapidly
blinking.
After the driver is found, start the West Mountain Radio
diagnostics utility program. Find the RIGrunner 4010S+ in
the list of devices. Right-click on the RIGrunner 4010S+
and select “TEST”. When the terminal window pops up,
press enter in the terminal area and the following menu will
appear:
West Mountain Radio 1.00
1) Reset to factory settings
2) View/Change Settings
3) Monitor mode
4) Force output ON
5) Force output OFF
Function <0>:
If enter “2”, followed by “ENTER, the following options occur:
Press just enter for no change:
High Trip <14.97>:
High Restart (14.81>:
Low Trip <10.97>:
Low Restart <12.96>:
Master Sensitivity (1-30) <15>:
Auto Restart when voltage is back in range <Y>?
Auto Shutdown when alternator is off <N>? y
Min alternator voltage <13.98>:
Delay in second <10>:
Auto turn on when alternator is on <N>?
Save new values <Y>?
NOTE: To determine the best master outlet sensitivity, use the
monitor mode. It will show real-time the value being read on the
master outlet. To exit monitor mode, press ESCape.