Note that each fuse position has a LED blown fuse indicator 

that will conveniently light up if an output fuse is blown. 

There must be power to the RIGrunner and a load on the 

circuit that has the blown fuse for the blown fuse LED to 

light.

Automatic or Manual Power Switching

The RIGrunner 4010S+ has a unique, high performance and 

convenient power switching system. It uses an electronically 

controlled solid state switch. This solid state switch is over 

current and over temperature protected. It should last 

indefinitely compared to a mechanical switch that suffers 

from arcing. The mechanical control switch in the RIGrunner 

carries none of the load.

The control switch has three positions: “OFF”, “AUTO” and 

ALL ON”. In the “OFF” position only the switched outlets are 

switched off. In the “AUTO” position the switched outlets 

will automatically turn on based on one of two auto modes 

described below. In the “ALL ON” position all of the switched 

outlets will be on regardless of what is connected to the 

master outlet. 

Auto Turn On/Off Modes:

• 

Master outlet mode:  As shipped, the RIGrunner 4010S+ 

operates in the master outlet current detect mode.  

Whenever adequate current is drawn from the master 

outlet, the other outlets will be on.  For example, if the 

primary radio is plugged in here and you turn that radio on 

the other outlets become active.  As shipped, the current 

threshold is set to detect 0.5A current draw.  The sensitivity 

of the current detect can be adjusted with the USB port. 

In order to make the unit super-sensitive, use a fuse 

that is rated for a lower current on the Master Outlet.  

The PWRguard feature does not protect Master Outlet. 

• 

Vehicle Detect mode:  Using the USB port the vehicle 

detect mode can be selected.  In this mode, the master 

outlet is not used for turn on/off control and is always 

on.  In this mode, the switched outlets are on whenever 

the vehicle alternator is running.  There is a 5 second 

delay before the outlets turn on.  After the vehicle 

alternator turns off there is a user programmable (via 

USB port) delay before the outlets turn off.  The USB 

port makes configurable to set the alternator voltage 

used to trigger this feature.  This mode only functions 

when the toggle switch is in the “Auto” position. 

Remote Control:

In the master outlet mode, a low current device may be 

connected to the master outlet and used to remotely turn 

the other outlets on and off.  For example, the RIGrunner 

4010S+ could be located in the vehicle trunk and a 15 foot 

cable connected to the master outlet to a PWRbrite at the 

front of the vehicle.  When the switch on the PWRbrite is 

turned on the RIGrunner 4010S+ will turn on the other outlets 

in the trunk.

West Mountain Radio does not know the power requirements 

of all radios and station accessories made.  Consult the 

owners manual for your unit or actually measure the power 

consumption.

A West Mountain Radio 

PWRcheck

 is a handy way to easily 

measure Volts,  Amps, Watts and Amp / hours all at the same 

time on one display.

A Red overvoltage indication is bad, DISCONNECT OR TURN 

OFF THE POWER SUPPLY IMMEDIATELY!  Overheating or 

damage a radio or other equipment may occur.   As supplied 

there is an audible alert, unlike other RIGrunners, on both 

undervoltage and overvoltage.

Summary of Contents for RIGrunner 4010S+

Page 1: ...io com 1020 Spring City Drive Waukesha WI 53186 262 522 6503 sales westmountainradio com 2015 West Mountain Radio All rights reserved All trademarks are the property of their respective owners RIGrunn...

Page 2: ...of current Locate your power source as close as possible to the RIGrunner Remember that every wire has resistance longer wires have more resistance More than a 10 run of 10 wire is not quite adequate...

Page 3: ...fuse will blow or make an undersized power supply unhappy The RIGrunner and any equipment plugged into the RIGrunner should go unharmed Using the proper fuses The RIGrunner 4010S comes supplied with a...

Page 4: ...nit super sensitive use a fuse that is rated for a lower current on the Master Outlet The PWRguard feature does not protect Master Outlet Vehicle Detect mode Using the USB port the vehicle detect mode...

Page 5: ...age On On Off Outlets are on but the voltage is high either the PWRguard jumper is out or not enough time has yet passed Off On On Outlets are on but the voltage is low and the PWRguard jumper is out...

Page 6: ...the driver is found start the West Mountain Radio diagnostics utility program Find the RIGrunner 4010S in the list of devices Right click on the RIGrunner 4010S and select TEST When the terminal wind...

Page 7: ...ends 15A Powerpole Connector 12 Pair 58257 1093 30A Powerpole Connector 12 Pair 58257 1095 45A Powerpole Connector 12 Pair 58257 1099 Powerpole Retention Clips 12 Pack 58257 1092 PowerLock RIGrunner...

Page 8: ...out charge and returned to you at our shipping expense Repaired or replaced items are warranted for the remainder of the original warranty period You will be charged for repair or replacement of the R...

Page 9: ...Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery Lifecycle Information CCS 58303 1609...

Reviews: