West Mountain Radio RIGrunner 4010S+ Manual Download Page 5

Operating Manual

The audible alert may be disabled by removing the internal 

jumper.  Store the unused jumpers on a single pin to not lose 

them for later use. 

Operational Reference

Switch Positions: 

 

Left:  

Unit off (except master outlet)

 

Center:  Auto mode

 

Right:   Unit on (unless voltage out of range) 

Internal Jumpers:

 

Top: 

Install to enable buzzer

 

Middle:  Install to enable PWRguard features. 

 

 

When removed, the power will not automatically

 

 

be turned off for out of range voltage.

 

Bottom:  Install for power saver option.  This will shut off all

 

 

LEDs and run at the lowest possible power when

 

 

the unit is off.

LED Patterns:

Red

Green Yellow

Off

Off

Off

No power to unit or unit is off and the 

power save jumper is in.

Off

On

Off

All outlets powered on.

Off

Dim

Off

Unit has power, outlets are off.

On

Off

Off

Outlets are off due to high voltage.

Off

Off

On

Outlets are off due to low voltage.

On

On

Off

Outlets are on but the voltage is high, 

either the PWRguard jumper is out or 

not enough time has yet passed.

Off

On

On

Outlets are on, but the voltage is low 

and the PWRguard jumper is out (off)

Off

On

Blink

Outlets are on, but the voltage is low, 

not enough time has passed to turn 

the outlets off.

Blink

Off

Off

Outlets are powered down, voltage 

is in range, but not yet down to the 

reset point.  Flip switch to OFF, then 

back to reset now.

Off

Off

Blink

Outlets are powered down, voltage 

is in range, but not up to the reset 

point.  Flip switch to OFF, then back 

to reset now.

Fast 

Blink

On

Off

Vehicle has been detected as not 

running and after the programmed 

time the unit power will shut off.

Off

Fast 

Blink

Off

Vehicle has been detected as run-

ning and after 5 seconds the unit 

power will turn on.

Any 

Status

Any 

Status

Fast 

Blink

The unit is connected to a PC via the 

USB port and the normal functions 

have been suspended.

Buzzer:

Sounds for 2 seconds every minute while the jumper is installed 

and the unit detects a low or high voltage while the outlets are 

Summary of Contents for RIGrunner 4010S+

Page 1: ...io com 1020 Spring City Drive Waukesha WI 53186 262 522 6503 sales westmountainradio com 2015 West Mountain Radio All rights reserved All trademarks are the property of their respective owners RIGrunn...

Page 2: ...of current Locate your power source as close as possible to the RIGrunner Remember that every wire has resistance longer wires have more resistance More than a 10 run of 10 wire is not quite adequate...

Page 3: ...fuse will blow or make an undersized power supply unhappy The RIGrunner and any equipment plugged into the RIGrunner should go unharmed Using the proper fuses The RIGrunner 4010S comes supplied with a...

Page 4: ...nit super sensitive use a fuse that is rated for a lower current on the Master Outlet The PWRguard feature does not protect Master Outlet Vehicle Detect mode Using the USB port the vehicle detect mode...

Page 5: ...age On On Off Outlets are on but the voltage is high either the PWRguard jumper is out or not enough time has yet passed Off On On Outlets are on but the voltage is low and the PWRguard jumper is out...

Page 6: ...the driver is found start the West Mountain Radio diagnostics utility program Find the RIGrunner 4010S in the list of devices Right click on the RIGrunner 4010S and select TEST When the terminal wind...

Page 7: ...ends 15A Powerpole Connector 12 Pair 58257 1093 30A Powerpole Connector 12 Pair 58257 1095 45A Powerpole Connector 12 Pair 58257 1099 Powerpole Retention Clips 12 Pack 58257 1092 PowerLock RIGrunner...

Page 8: ...out charge and returned to you at our shipping expense Repaired or replaced items are warranted for the remainder of the original warranty period You will be charged for repair or replacement of the R...

Page 9: ...Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery Lifecycle Information CCS 58303 1609...

Reviews: