Safety instructions
• "The appliance is exclusively intended for the designated use described in
article 2 "Function". Other applications are prohibited, as inappropriate use
can result in dangerous situations.
• National safety and accident and assembly regulations must be observed.
• In case of equipment failure, additional safety precautions should be taken
to avoid possible danger to persons or damage to property.
• Wiring must be carried out by a qualified electrician. Adhere to relevant
regulations!
• The connection to external supply lines must be carried out using a
screwed cable gland (M20 x 1.5) in the terminal box under the cover (see
drawings from page 20). Install a fixed connection cable if an unprotected
or flexible cable is used.
• Turn off the power supply and take steps to ensure against further acciden-
tal use:
- Before connection.
- In the event of damage
• Only operate the appliance when completely assembled and undam-
aged. Do not drill into or interfere with the explosion-proof housing in any
way.
• Damage can invalidate the type of protection, i.e. the explosion protec-
tion.
• Observe the nominal voltage.
• The length of the air gap for the potential transmission of the igniting flame
is greater than that required by EN 60079. Information on the dimensions
can be obtained from the manufacturer.
•
785:
Observe the waiting times indicated of 5 minutes before you open the
housing.
•
785:
When replacing the halogen bulbs only use bulbs with a power con-
sumption of 20 W.
• "With feed-through wiring the current fed through the terminal must be lim-
ited to 16 A, see chart 6.4, "Electrical Data" on page 11.
6
Technical specifications
6.1
Technical specifications
Material
Housing:
AIMgSi1 DIN1725 T1 saltwater-proof,
powder-coated /
dome
: glass
Accessories
: stainless VA-steel
Total dimensions
Ø
140 mm x H 215 mm
Weight
729
: 2900 g
785
: 2900 g
Protection class
I
Temperature range
Explosion protection
-50 °C ... +50 °C
Temperature range
729
: -40 °C ... +50 °C
785
: -30 °C ... +50 °C
Protection type
100 %
Protection type
IP 66, according to IEC 60529 and EN/IEC 60079-31
OFF
NENNSPANNUNG
NOMINAL VOLTAGE
TENSION NOMINALE
310_729_001_1111.fm Seite 10 Freitag, 2. Dezember 2011 11:58 11
Summary of Contents for 729
Page 21: ...21 4 5 310_729_001_1111 fm Seite 21 Freitag 2 Dezember 2011 11 58 11 ...
Page 25: ...Anhang Appendix Annexes 25 310_729_001_1111 fm Seite 25 Freitag 2 Dezember 2011 11 58 11 ...
Page 26: ...Anhang Appendix Annexes 26 310_729_001_1111 fm Seite 26 Freitag 2 Dezember 2011 11 58 11 ...
Page 27: ...Anhang Appendix Annexes 27 310_729_001_1111 fm Seite 27 Freitag 2 Dezember 2011 11 58 11 ...
Page 28: ...Anhang Appendix Annexes 28 310_729_001_1111 fm Seite 28 Freitag 2 Dezember 2011 11 58 11 ...
Page 29: ...Anhang Appendix Annexes 29 310_729_001_1111 fm Seite 29 Freitag 2 Dezember 2011 11 58 11 ...
Page 30: ...Anhang Appendix Annexes 30 310_729_001_1111 fm Seite 30 Freitag 2 Dezember 2011 11 58 11 ...
Page 31: ...Anhang Appendix Annexes 31 310_729_001_1111 fm Seite 31 Freitag 2 Dezember 2011 11 58 11 ...