http://www.wenshing.com.tw ; http://www.rf.net.tw
RD-485
Instruction Manual P.11
Means for
switching 4
Means for
switching 3
Means for
switching 2
Means for
switching 1
Rate
Interface
0
0
0
0
1.2Kbps
RS232
0
0
0
1
2.4Kbps
RS232
0
0
1
0
4.8Kbps
RS232
0
0
1
1
9.6Kbps
RS232
0
1
0
0
19.2Kbps
RS232
0
1
0
1
38.4Kbps
RS232
0
1
1
0
56Kbps
RS232
0
1
1
1
115.2Kbps
RS232
1
0
0
0
1.2Kbps
RS485
1
0
0
1
2.4Kbps
RS485
1
0
1
0
4.8Kbps
RS485
1
0
1
1
9.6Kbps
RS485
1
1
0
0
19.2Kbps
RS485
1
1
0
1
38.4Kbps
RS485
1
1
1
0
56Kbps
RS485
1
1
1
1
115.2Kbps
RS485
Table 1.
Setup Rate and Frequency Mode
Press the set button (SETUP KEY), RD-485 entry into set mode. Work LED
lights flash, Link LED lights-out, and then PC or micro-controller may be RS485
or RS232 interface under instructions to amend RD-485 wireless transmission
frequency and wireless transmission rate. After RD-485 settings will be
automatically deposited, it will return to have completed at the same data, and
return of a PC or microcontrollers at finally.
Instruction Format
Frequency and wireless transmission rate of 0XABCDEFGHIJKLMNOP
written instructions were 8 bytes with 16-band. If it is more than 8 bytes, less
than 8 bytes or before the 2 bytes is not equivalent to 0x1234, the RD-485 are
disregarded.
ABCD is fixed leader orders for its information "1234 H".
E is fixed at 0 H.
F is for the wireless transmission rate settings.
WENSHING