High-Performance Distance Sensor
Designation
Function
Key designation
Impulse
Adjusting impulse duration
+
–
Impulse duration defines how long the
output signal remains in the activated
state. Impulse duration can be set to a
value within a range of 0 to 10.000 ms
by pressing the + or the – key. After
the selected impulse duration has
elapsed, the output signal is returned
to the deactivated state..
Function can be combined with
ON Delay.
Extern T
External Teach-In
By pressing the button
can be selected, if an “Object Teach-In”, a “Background
Teach-In”, or “Teach-In of a tolerance window” is executed at the External Teach-In.
7.4. A3 Error F/A3 Input
7.4.1. A3 Error
The error output is activated if no light signal is returned to the Sensor.
Designation
Function
Key designation
NPN/PNP
Output configuration
P
N
The error output is set to PNP, push-pull or NPN by pressing the
P or the N key. The respective circuit
diagram is displayed.
NPN/PNP
Output configuration
NO
NC
The error output is set up as normally open or normally closed by pressing the
NO or the NC key.
The respective circuit diagram is displayed.